3-54
Diagnostic Tools
The following ASR-2 flow chart shows you the sequence of events after a hardware or software
error occurs:
If the server continues experiencing
hardware/software errors and the
number of ASR cycles exceed the
specified number of recovery
attempts, the server logs an error to
the Server Health Log or the
Integrated Management Log and
boots the Compaq Utilities from the
system partition on the hard drive
Figure 3-1. ASR-2 flow chart
Hardware/Software error occurs
Error records in the Critical Error Log,
or the Integrated Management Log,
If a modem is installed and paging
Notification pager alert is sent to
|
Unattended server boots the
Operating System
|
depending on your server
configuration.
|
Operating System halts normal
operation
|
ASR Timer expires
|
Server is reset
|
is enabled, the Server Failure
the Server Administrator
---Or---
Server boots the Compaq Utilities
If a modem is installed, ASR puts
the modem on auto answer so that
the Server Administrator can dial in
(using third party terminal emulator
on the system partition on the
hard drive
|
software) to remotely run the
Compaq Utilities to identify the
source of the fault
|
Or
|
Local Server Administrator runs
Compaq Utilities from server
console to identify the source
of the fault