DAAD Diagnostic Messages
Message
Description
Drive (bay) X
Firmware on this physical drive is below
firmware needs
the latest recommended version.
upgrading
Drive (bay) X has
Physical drive has invalid monitor and
invalid M&P
performance data.
stamp
Drive X indicates
Message indicates which physical drive
position Y
appears to be scrambled or in a drive
bay other than the one for which it was
originally configured.
Drive (bay) X RIS
The copies of the RIS on this drive do
copy mismatch
not match.
Drive (bay) X
An error occurred while DAAD was
upload code not
trying to read the upload code
readable
information from this drive.
Drive (bay) X has
The array controller could not
loose cable
communicate with this drive at power-
up. This drive has not previously failed.
Drive (bay) X is a
This drive has been replaced. This
replacement drive
message displays if a drive is replaced
in a fault tolerant logical volume.
Drive (bay) X is a
This drive has been replaced and
replacement drive
marked OK by the firmware. This may
marked OK
occur if a drive has an intermittent
failure (for example, if a drive has
previously failed, then when DAAD is
run, the drive starts working again).
Drive (bay) X is
The indicated physical drive has failed.
failed
Drive (bay) X has
Drive has insufficient capacity to be
insufficient
used in this logical drive configuration.
capacity for its
configuration
Drive (bay) X is
This drive is being rebuilt from the
undergoing drive
corresponding mirror or parity data.
recovery
Continued
Recommended Action
Run the Options ROMPaq Utility to upgrade the drive
firmware to the latest revision.
Run the System Configuration Utility to properly initialize
this drive.
Examine the graphical drive representation on DAAD to
determine proper drive locations. Remove drive X and
place it in drive position Y. Rearrange the drives
according to the DAAD instructions.
This drive may need to be replaced. Check for
other errors.
If there were multiple errors, this drive may need to
be replaced.
Check all cable connections first. The cables could be
bad, loose, or disconnected. Turn on the system and
attempt to reconnect signal/power cable to the drive. If
this does not work, replace the cable. If that does not
work, the drive may need to be replaced.
If the replacement was intentional, allow the drive
to rebuild.
Replace the drive.
Replace this drive.
Replace this drive with a larger capacity drive.
Normal operations should occur.