Download Print this page

Kenmore 7755 - Elite 30 in. Dual Fuel Range Installation Instructions Manual page 8

Freestanding dual fuel
Hide thumbs Also See for 7755 - Elite 30 in. Dual Fuel Range:

Advertisement

Available languages

Available languages

Range
installation
instructions
OR _S _ 3-Wire connection
instructions
(for existing
installations
ONLY
See Fig. 34)
Power
Cord
Connection
1.
Followthemanufacturer'sinstallationinstructions
supplied with the strain relief and install (Also see
Figs. 29, 30 & 31).
2.
Insert the end connectors for Line 1, Line 2 and Neutral
and tighten securely to the terminal block (See Fig. 34).
iMPORTANT
NOTE: DO NOT LOOSEN the factory
installed nut connections
which secure the range
wiring to the terminal block. Electrical failure or loss of
electrical connection
may occur if these 3 nuts are
loosened or removed.
3.
Make sure all connections
are tightened securely and
replace the rear access cover (See Fig. 30).
Grounding
instructions
(for 3-Wire
connections
ONLY)
A ground strap is installed on this range which connects
the center terminal of the terminal block (neutral) to the
range chassis. The ground strap is connected to the range
by the center, lowest screw (See Fig. 34). The ground strap
must not be removed unless national or local codes do not
permit use of ground strap.
NOTE:
If the ground strap is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
For 3 & 4=Wire permanent
connections
ONLY
3 = Wire permanent
connection
= follow
Steps
1,2 & 5 below.
4 - Wire permanent
connection
= follow
Steps
1 thru 5 below.
Before wiring the range, review the suggested power
source location drawings in Fig. A & B. If connecting
to a
4-Wire electrical system (new branch-circuit
or mobile
home requires 4-Wire connection):
1.
(3 & 4 =Wire permanent
connections)
Follow the
manufacturer's
installation instructions supplied with
the strain relief and install.
4-Wire
Connection
3 Factory installed connections
(DO NOT LOOSEN)
Terminal
block
Connect
line 1
here
Cut ground
strap,
ground strap
& ground plate
Connect
gre_
insulated copper
ground wire with
ground screw here
NOTES:
Install strain-relief
bushing.
Center or white
wire must always be
attached to the center
terminal
on block
Connect
neutral
(white or
center) here
Connect
line 2
here
Fig. 33
3-Wire Connection
Connect
line 1
here
Terminal
block
3 Factory installed connections
(DO NOT LOOSEN)
Connect
neutral
(white or
center) here
Ground
strap
Ground
screw
& ground
NOTES:
Install strain-relief
bushing.
Center or white
wire must always
be
attached to the center
terminal
on block
Connect
line 2
here
Fig. 34
8

Advertisement

loading

This manual is also suitable for:

7755 30