Back Panel Layout; Power And Ground - PRESONUS ADL600 User Manual

High voltage tube preamp
Hide thumbs Also See for ADL600:
Table of Contents

Advertisement

2 . 2 B A C K P A N E L L A Y O U T
Connectors
All Input and Output connectors are transformer balanced. XLR with the following
wiring standard:
NOTE: The LINE INPUT does not pass signal unless the INPUT selector switch
is set to LINE on the front panel.
2 . 3 P O W E R A N D G R O U N D
AC POWER: Your ADL 600 accepts a standard IEC cord. Note: The input power
voltage is set at the factory to correspond with the country in which it was
shipped. The main fuse is located above the IEC receptacle. (110-120V uses
3.5A , 220-240V uses 1.5A. Two additional fuses located on the power supply
printed circuit board inside the chassis to protect the high voltage power supply
are 200mA. All fuses are fast-acting 250VAC, 5mm x 20mm.
CHASSIS GND LINK: By removing the metal strap attached by two phillips head
screws, the electrical ground from the chassis is lifted. The ADL will then find a
common ground. This is helpful if you hear a ground hum caused by a ground
loop.
CONTROLS & CONNECTIONS
XLR
PIN 1
GND
PIN 2
High
(+)
PIN 3
Low
(-)
8