Carrier Infinity Series Wiring Diagrams
Carrier Infinity Series Wiring Diagrams

Carrier Infinity Series Wiring Diagrams

Heat pump with puron refrigerant 2 to 5 nominal tons
Hide thumbs Also See for Infinity Series:

Advertisement

Quick Links

25HNA6
Infinityt Series Heat Pump
with Puronr Refrigerant
2 To 5 Nominal Tons
VIO
CL
BLU
SR
11
21
GRY
GRY
C C
BLK
BRN/YEL
CH
L1
BRN
208/230 1Ø
11
21
L2
POWER
23
23
SUPPLY
RED
C C
EQUIP GND
RED/WHT
YEL
BRN/YEL
YEL/BLU
VS
BLU
YEL/PNK
2
YEL/PNK
1
LPS
PL2
BLU/PNK
2
1
BLU/PNK
HPS
PL3
GRY
3
SR
GRY
1
PL4
LED
T1
4
BRN/YEL
C
3
YEL/BLU
LO
2
RED/WHT
1
HI
COMM STATUS
PL5
* UC (WITH INFINITY/EVOLUTION ONLY)
PL7
CONNECT TO
R AND Y2 ON
A B C D R
CONTROL BOARD
TO INDOOR UNIT
-LEGEND-
FACTORY POWER WIRING
CB
CCH
FIELD POWER WIRING
CH
FACTORY CONTROL WIRING
CL
FIELD CONTROL WIRING
COMM
COMPONENT CONNECTION
COMP
JUNCTION
HPS
LPS
FIELD SPLICE
LS
CAPACITOR
CAP
* MAY BE FIELD INSTALLED
FLASH
FAULT DEFINITION
CODE
On, No Flash
Standby
1, Pause
Low Stage
2, Pause
High Stage
System Communications Failure
16
25
Invalid Model Plug
31
High Pressure Switch Trip
32
Low Pressure Switch Trip
45
Control Fault
46
Brown out (230V)
47
No 230v with call to run
53
Outdoor Air Temp Sensor
55
Coil Temp Sensor
56
Temp Sensor Range Error
Wiring Diagrams
CONNECTION
BLU
DIAGRAM
6
BLU
8
YEL
COMP
2
S
C
4
COMP
BLU
R
CAP
YEL
SC
YEL
BLK
BRN
OFM
BRN
CCH
FAN
CAP
BRN
YEL
BLK
RED
YEL
ODF
L2
L1
CCH
VR
YEL
VIO BLK
RED
PWM1
BRN
YEL
PWM2
BLU
PL1
CB
C
1
RVS
2
3
SEV
TIME
DEFROST
4
C
(MIN)
TIME
1
LED
2
OCT
3
4
ON
OFF
OAT
(DEFAULT)
QUIET
5
SHIFT
PL6
FORCED
DEFROST
P8
W1
O
Y1 Y2
C
MODEL PLUG
CONTROL BOARD
OAT
CRANKCASE HEATER
OCT
CONTACTOR HIGH CAPACITY
OFM
CONTACTOR LOW CAPACITY
RVS
SYSTEM COMMUNICATION
SC
COMPRESSOR
SEV
HIGH PRESSURE SWITCH
SR
LOW PRESSURE SWITCH
STATUS SYSTEM FUNCTION LIGHT
LIQUID SOLENOID
* UC
*
FLASH
FAULT DEFINITION
CODE
71
Low Stage Thermal Cutout
72
High Stage Thermal Cutout
73
Contactor Shorted
75
Low Stage didn't start
76
Low Stage didn't start 3 times
77
High Stage didn't start
78
High Stage didn't start 3 times
81
Low Stage thermal lockout (4 HRS)
82
High Stage thermal lockout (4 HRS)
83
Low pressure lockout (4 HRS)
84
High pressure lockout (4 HRS)
85
Low contactor open
87
High contactor open
Fig. 1 – Wiring Diagram — Model sizes 2- -4 tons, 208/230- -1
SCHEMATIC
L1
DIAGRAM
(LADDER FORM)
COMPONENT ARRANGEMENT
FAN
COMP
CAP
CAP
EQUIP
GND
SR
SC
CL
CONTROL
CH
BOARD
MODEL PLUG CHART
MODEL MODEL
PIN RESISTANCE (K
)
SIZE
PLUG
1 - 4 (R1)
2 - 3 (R2)
HK70EZ
024
002
5. 1
18
5. 1
036
004
33
006
5. 1
51
048
LPS
HPS
RVS
ORG
SR
ORG
T1
OCT
C
LO
BRN
CL
HI
CH
BRN
BLK
BLK
OAT
NOTES:
1. COMPRESSOR FURNISHED WITH INHERENT THERMAL PROTECTION.
*LS
2. FAN MOTOR FURNISHED WITH INHERENT THERMAL PROTECTION.
3. TO BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.) AND LOCAL CODES.
4. OUTDOOR UNIT CONTROL REQUIRES A MINIMUM OF 27 VA, 24 VAC CONTROL POWER.
5. USE COPPER CONDUCTORS ONLY. USE CONDUCTORS SUITABLE FOR AT LEAST 70ºC (167ºF).
THERMISTOR (OUTDOOR AIR)
6. IF INDOOR SECTION HAS A TRANSFORMER WITH A GROUNDED SECONDARY, CONNECT THE
THERMISTOR COIL
GROUNDED SIDE TO "C".
OUTDOOR FAN MOTOR
7. IF ANY OF THE ORIGINAL WIRE, AS SUPPLIED, MUST BE REPLACED, USE THE SAME OR EQUIVALENT WIRE.
8. CHECK ALL ELECTRICAL CONNECTIONS INSIDE CONTROL BOX FOR TIGHTNESS.
REVERSING VALVE SOLENOID
9. DO NOT ATTEMPT TO OPERATE UNIT UNTIL SERVICE VALVES HAVE BEEN OPENED (BACK SEATED).
START CAPACITOR
10. MUST USE THERMOSTAT LISTED IN PRE-SALE LITERATURE.
SOLENOID EXPANSION VALVE
11. COMPRESSOR WINDINGS SHOWN FOR 2 CYLINDER OPERATION. FOR 1 CYLINDER OPERATION
START RELAY
REVERSE R AND S MARKINGS.
UTILITY CURTAILMENT
THIS CONTROL BOARD CONTAINS A FIVE MINUTE SHORT CYCLE PROTECTOR. A FIVE MINUTE DELAY WILL
OCCUR BETWEEN COMPRESSOR OFF/ON CYCLES. TO BYPASS DELAY, SHORT FORCED DEFROST PINS
FOR 1 SECOND THEN RELEASE.
SHORT FLASHES
1 MINUTE TIME DELAY - WHEN CHANGING FROM LOW TO HIGH OR HIGH TO LOW. THERE IS A 1 MINUTE
TIME DELAY DURING CAPACITY CHANGE, THE OUTDOOR FAN WILL REMAIN RUNNING.
INDICATE THE FIRST
CRANKCASE HEATER - OPERATES DURING OFF CYCLE.
DIGIT IN THE STATUS
DEFROST TIME SELECTION - (SHOWN AS DT ON BOARD) THE DEFROST INTERVAL TIME CAN BE FIELD
CODE, FOLLOWED BY
SELECTED, DEPENDENT UPON LOCAL GEORGRAPHIC REQUIREMENTS. IT IS FACTORY SET AT 90 MINUTES
LONG FLASHES
AND CAN BE CHANGED TO EITHER 30, 60 OR 120 MINUTES.
INDICATING THE
DEFROST - DEFROST WILL ONLY BE PERFORMED AT OUTDOOR TEMPERATURES LESS THAN 50ºF DEFROST
WILL INITIATE WHEN TIME SELECTED HAS ELAPSED AND THE COIL TEMPERATURE IS LESS THAN 32ºF (+/-2º)
SECOND DIGIT OF
AND WILL TERMINATE AT 65ºF (+/-5º) UPON DEFROST TERMINATION THE OUTDOOR FAN WILL DELAY 20
SECONDS BEFORE STARTING.
THE STATUS CODE.
FIELD INITIATED FORCED DEFROST - (SHOWN AS FORCED DEFROST ON BOARD) BY PLACING A JUMPER
ACROSS THE FORCED DEFROST TERMINALS FOR 5 SECONDS, OR LONGER, AND THEN REMOVING THE
JUMPER THE UNIT WILL INITATE A DEFROST CYCLE REGARDLESS OF COIL TEMPERATURE THE DEFROST
CYCLE WILL TERMINATE AT 65ºF (+/-5º) IF COIL TERMPERATURE IS ABOVE 32ºF OR OUTDOOR AMBIENT
332243-101 REV. D
TEMPERATURE IS ABOVE 50ºF, DEFROST MODE WILL TERMINATE AFTER 30 SECONDS OF ACTIVE MODE.
C L
21
11
SR
6
COMP
CAP
8
2
4
SC
CH
11
21
ODF
VS
L2
L1
VR
BLU
VIO BLK
BRN
YEL
2
CLU
1
PL2
CB
2
1
PL3
TIME
DEFROST
3
(MIN)
TIME
1
PL4
LED
LED
4
3
2
ON
OFF
1
(DEFAULT)
QUIET
COMM STATUS
SHIFT
PL5
PL7
FORCED
DEFROST
A B C D R
O
W1
Y1 Y2
C
TO INDOOR UNIT
UNIT OPERATION
L2
COMP
S
CH
C
R
23
23
FAN
CAP
OFM
CCH
CCH
YEL
RED
PWM1
PWM2
RVS
BLU
PL1
C
1
RVS
2
3
SEV
4
C
OCT
1
2
OCT
3
OAT
4
OAT
5
PL6
*LS
P8
MODEL PLUG

Advertisement

loading
Need help?

Need help?

Do you have a question about the Infinity Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Carrier Infinity Series

  • Page 1 25HNA6 Infinityt Series Heat Pump with Puronr Refrigerant 2 To 5 Nominal Tons Wiring Diagrams SCHEMATIC CONNECTION DIAGRAM DIAGRAM COMP COMP (LADDER FORM) COMP COMPONENT ARRANGEMENT BRN/YEL COMP COMP EQUIP 208/230 1Ø POWER SUPPLY CONTROL BOARD EQUIP GND MODEL PLUG CHART RED/WHT MODEL MODEL PIN RESISTANCE (K...
  • Page 2 Fig. 1 – Wiring Diagram — Model size - - 5 tons, 208/230- -1 Catalog No: 25HNA6---2W Copyright 2006 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 09/09 Replaces: 25HNA6--- 1W Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

This manual is also suitable for:

Infinity 25hna6