2-stage heat pump with puronr refrigerant 2 to 5 nominal tons

Advertisement

Quick Links

25HNB9
Infinityr 19 2---Stage Heat Pump
with Puronr Refrigerant
2 to 5 Nominal Tons
CS
BLU
RED
RED
TRAN 24V
BRN
230V
BLK 208V
CCH
BLK
BLK
L1
11
21
208/230 1Ø
L2
POWER
23 23
SUPPLY
C C
EQUIP GND
CONT
RED/WHT
BRN/YEL
YEL/PNK
2
1
LPS
YEL/PNK
PL2
RED
RED
2
1
DTS
PL3
RED
3
BLU/PNK
SR
BLU/PNK
1
HPS
PL4
BRN
T1
4
BRN/YEL
C
3
LO
RED/WHT
2
HI
1
BLU
PL5
OPTIONAL
PL7
NON-COMMUNICATING
CONTROL
SEE NOTE #10
R C W1 Y1 Y2 O
TO INDOOR UNIT
LEGEND
FACTORY POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
COMPONENT CONNECTION
FIELD SPLICE
JUNCTION
CAPACITOR
CAP
CB
CONTROL BOARD
CRANKCASE HEATER
CCH
CHS
CRANKCASE HEATER SWITCH
SYSTEM COMMUNICATION
COMM
COMP
COMPRESSOR
CONTACTOR
CONT
* MAY BE FIELD INSTALLED
UNIT OPERATION
This control board contains a five minute short cycle protector. A five minute delay will
occur between compressor off/on cycles. To bypass delay, short forced defrost pins
for 1 second then release. The crankcase heater is energized during off cycle below 65ºF.
Defrost time selection - (shown as DT on board) the defrost interval time can be field
selected, dependent upon local georgraphic requirements. It is factory set at 90 minutes
and can be changed to either 30, 60 or 120 minutes.
Defrost - defrost will only be performed at outdoor temperatures less than 50ºF defrost
will initiate when time selected has elapsed and the coil temperature is less than 32ºF
(+/-2º) And will terminate at 65ºF (+/-5º) upon defrost termination the outdoor fan will delay
20 Seconds before starting.
Field initiated forced defrost - (shown as forced defrost on board) by placing a jumper
across the forced defrost terminals for 5 seconds, or longer, and then removing the
jumper the unit will initate a defrost cycle regardless of coil temperature the defrost
cycle will terminate at 65ºF (+/-5º) if coil termperature is above 32ºF or outdoor ambient
temperature is above 50ºF, defrost mode will terminate after 30 seconds of active mode.
Wiring Diagram
CONNECTION
BLU
*SR
*SC
BRN
YEL
2 1
5
CAP
BLK
COM
YEL
CHS
BLK
BLK
BLU
BLK
BLK
VIO
BLK
YEL
YEL
YEL
BLK
BRN
GRN/YEL
YEL
BLU
VS
VR
L2
L1
CCH
ODF
VIO BLK
RED
BLU
BRN
YEL
CB
PL1 BLU
C
1
TIME
DEFROST
RVS
(MIN)
TIME
SEV
C
LED
LED
OFF
1
ON
(DEFAULT)
OCT
2
COMM STATUS
QUIET
SHIFT
4
OAT
AS PROVIDED
BY MANUFACTURER
5
PL6
SEE NOTE #11
A B C D
R C
W1
Y2 O
Y1
FORCED
DEFROST
P8
MODEL PLUG
*UC (WITH INFINITY/EVOLUTION ONLY)
CONNECT TO
R AND Y2 ON
CONTROL BOARD
CS
COMP HIGH CAP SOLENOID
DISCHARGE TEMP SWITCH
DTS
HPS
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
LPS
* LS
LIQUID SOLENOID
THERMISTOR (OUTDOOR AIR)
OAT
OCT
THERMISTOR COIL
OUTDOOR FAN MOTOR
OFM
RVS
REVERSING VALVE SOLENOID
START CAPACITOR
SC
SEV
SOLENOID EXPANSION VALVE
START RELAY
SR
SYSTEM FUNCTION LIGHT
STATUS
TRAN
TRANSFORMER
UTILITY CURTAILMENT
* UC
Fig. 1 – Wiring Diagram — Model sizes 2 - - 5 tons, 208/230- -1
SCHEMATIC DIAGRAM (LADDER FORM)
DIAGRAM
CCH
L1
CONT
COMP
11
21
EQUIP
GND
*SR
2 1
5
VS
2
OFM
1
LPS
PL2
BLU
2
1
DTS
PL3
YEL
3
LED
SR
1
YEL
HPS
PL4
T1
4
PWM1
COMM STATUS
C
3
PWM2
LO
2
CONT
1
AS PROVIDED
HI
RVS
PL5
BY MANUFACTURER
ORG
SEE NOTE #11
CS
A B C D
2
ORG
PL7
3
4
OCT
OPTIONAL
BRN
NON-COMMUNICATING
BRN
CONTROL
SEE NOTE #10
BLK
R C W1 Y1 Y2 O
TO INDOOR UNIT
BLK
OAT
MODEL PLUG CHART
MODEL
MODEL
*LS
SIZE
HK70EZ
024
036
048
060
FLASH
FAULT DEFINITION
CODE
On, No Flash Standby
Low Stage
1, Pause
High Stage
2, Pause
3, Pause
ODU Fan Delay Defeat Not Active
4, Pause
ODU Fan Delay Defeat Active
5, Pause
Brown Out is Disabled
6, Pause
Brown Out is Active
System Communications Failure
16
Invalid Model Plug
25
High Pressure Switch Trip or
31
Disch Temp Switch Trip
32
Low Pressure Switch Trip
Control Fault
45
46
Brown out (230V)
Short flashes indicate the first digit in the status code, followed by long flashes indicating the second digit of
the status code.
NOTES:
1. Compressor furnished with inherent thermal protection.
2. To be wired in accordance with National Electric Code (N.E.C.) and local codes.
3. Outdoor unit control requires a minimum of 27 va, 24 vac control power.
4. Use copper conductors only. Use conductors suitable for at least 70ºC (167ºF).
5. If indoor section has a transformer with a grounded secondary, connect the grounded side to "C".
6. If any of the original wire, as supplied, must be replaced, use the same or equivalent wire.
7. Check all electrical connections inside control box for tightness.
8. Do not attempt to operate unit until service valves have been opened (Back Seated).
9. MUST USE THERMOSTAT OR USER INTERFACE LISTED IN PRE-SALE LITERATURE ONLY.
10. In case of non-communicating indoor system disconnect factory provided wires from A, B, C, and D
terminals. Use factory provided wires to connect to R, C, W1, Y1, Y2, and O as required by
installation instructions. Cap or remove unused factory provided wires.
11. For communicating control only.
TRAN 230V
CHS
CONT
C
230V
23
COMP CAP
COMP
*SC
OFM
YEL
L2
VR
L1
ODF
CCH
PWM1
CB
PWM2
BLU
PL1
TIME
(MIN)
C
1
DEFROST
2
RVS
TIME
3
SEV
4
C
LED
OFF
ON
1
(DEFAULT)
QUIET
OCT
2
SHIFT
OAT
4
5
PL6
FORCED
R C
Y2 O
W1
Y1
DEFROST
P8
MODEL PLUG
CONTROL
BOARD
PIN RESISTANCE (K
)
PLUG
TRAN
1 - 4 (R1) 2 - 3 (R2)
5.1
10
120
12
5.1
180
CONT
14
5.1
270
11
16
5.1
FLASH
FAULT DEFINITION
CODE
No 230v with call to run
47
Outdoor Air Temp Sensor
53
55
Coil Temp Sensor
56
Temp Sensor Range Error
Low Stage Thermal Cutout
71
72
High Stage Thermal Cutout
73
Contactor Shorted
Contactor Open (No 230v to Comp)
74
81
Low Stage thermal lockout (4 HRS)
82
High Stage thermal lockout (4 HRS)
Low pressure lockout (4 HRS)
83
84
High pressure lockout (4 HRS)
338865-101 REV. A
L2
23
RVS
OCT
OAT
*LS

Advertisement

loading
Need help?

Need help?

Do you have a question about the Infinity 19 and is the answer not in the manual?