Kenmore 7560 30" Gas Range Installation Instructions Manual

30" gas range

Advertisement

Quick Links

iNSTALLATiON
AND SERVICE
MUST BE PERFORMED
BY A QUALiFiED
iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL ELECTRICAL
INSPECTOR'S
USE.
READ AND SAVE THESE
iNSTRUCTiONS
FOR FUTURE
REFERENCE.
if the information in this manual is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY:
=
Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
=
WHAT TO DO iF YOU SMELL GAS:
• Do not try to light any appliance.
= Do not touch any electrical switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• if you cannot reach your gas supplier, call the fire
department.
=
Installation and service must be performed bya qualified
installer, service agency or the gas supplier.
e ALL RANGES
CAN TiP
• INJURYTO
PERSONS
COULD
RESULT
• iNSTALL
ANTI=TIP
DEVICE
PACKED
WiTH
RANGE
• SEE iNSTALLATiON
iNSTRUCTiONS
RANGE
OVERALL
DIMENSIONS
253/4"
47-3/4"
Maximum
36 + 1/8"
FRONT
Wall
on Either
Side of Range
Above
36"
Height.
* Note:
3"
30"
Clearance
Minimum
if Equipped
2"
with
11000
or
greater
BTU Burners.
SIDE
VIEW
t
Minimumto
14-13"-_1
18"
Cabinets
on
Maximum
Depth
Either Side
for Cabinets
of Range.
Above
Range Top.
Clearances
and Dimensions
1.
Location--Check
location where
the range will be installed. Check
for
proper
electrical
and
gas
supply, and the stability of the
floor.
2.
Dimensions
that are shown must
be used.
Given
dimensions
provide
minimum
clearance.
Contact
surface
must
be solid
and level.
PIN 316259314 (0112)
Provide
Proper Fuel Type
Before Proceeding: Your range is preset to operate on natural gas only.
This
model was shipped convertible
from the factory with the necessary
parts and
conversion instructions supplied,
DO NOT attempt to convert this range to L P/Propane settings without
the proper LP/Propane conversion kit provided with the range or obtained from your
dealer,
Follow all instructions provided with this conversion kit.
EspaSoI-Paginas9-16

Advertisement

Table of Contents
loading

Summary of Contents for Kenmore 7560 30" Gas Range

  • Page 1 iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER. iMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE iNSTRUCTiONS FOR FUTURE REFERENCE. if the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 2: Important Safety Instructions

    Important Notes to the Installer Never leave children alone or unattended Read all instructions contained in these installation in the area where an appliance is in use. As children grow, instructions before installing range. teach them the proper, safe use of all appliances. Never leave Remove all packing material from the oven compartments the oven door open when the range is unattended.
  • Page 3: Before Starting

    A. Locate the Bracket Using the Template- (Bracket may Before Starting be located on either the left or right side of the range. Use Tools You Will Need the information below to locate the bracket if template is For leveling legs and Anti-Tip Bracket: not available).
  • Page 4 Level and Position Range- Level range by adjusting the (4) leveling legs with a wrench. Note: A minim um clearance of 1/8" is required between the bottom of the range and the leveling leg to allow room for the bracket. Use a spirit level to check your adjustments.
  • Page 5 Read electrical connection details below Manual Flare Flexible Flare Union Pressure and connect electricity to range. Shutoff Union Appliance Adaptor Regulator Valve Conduit Before servicing, disconnect electrical supply at circuit breaker, fuse or power cord. Electric Requirements: An individual, properly grounded and polarized branch circuit protected by a 15 amp.
  • Page 6 Operation of Surface Burners Electric Ignition Surface Burners Operation of electric igniters should be checked after range 6. Installation of Surface Burner Caps and supply line connectors have been carefully checked for Your range is equipped with any combination of the sealed leaks and range has been connected to electric power.
  • Page 7 appear at the oven burner. There is a time lapse from 30 to 60 8. Adjust the "LOW" Setting of Surface Burner seconds after the thermostat is turned ON before the flame Valve (Linear Flow Valves Only): appears at the oven burner. When the oven reaches the dial setting, the glowing igniter will go off.
  • Page 8: Care & Cleaning

    Care, Cleaning and Maintenance Oven Refer to the Use & Care Guide for cleaning instructions. Burner Tube If removing range is necessary for cleaning maintenance, shut off gas supply. Disconnect the gas and electrical supply. If the gas or electrical supply is inaccessible, lift the unit slightly at the front and pull out away from the wall.

This manual is also suitable for:

7560

Table of Contents