(If your appliance
is equipped
with
a
white
neutral
conductor.)
This appliance
is manufactured
with
a white
neutral
power
supply and a frame connected
copper wire.
The frame is grounded
by connection
of grounding
lead to neutral
lead at the termination
of the
conduit,
if used in USA, in a new branch circuit
installation
(1996 NEC), mobile
home, recreational
vehicles, where
local code do not permit grounding
trough
the neutral
(white)
wire or in Canada,
disconnect
the white
and green lead from each
other and use ground
lead to ground
unit in
accordance
with
local codes, connect
neutral
lead
to branch circuit-neutral
conductor
in usual manner
see Figure 4. If your appliance
is to be connected
to a 3 wire grounded
junction
box (US only),
where
local code permit connecting
the appliance-
grounding
conductor
to the neutral
(white)
see
Figure
3.
NOTE TO ELECTRICIAN: The armored cable leads
supplied with the appliance are UL-recognized for
connection to larger gauge household wiring• The
insulation of the leads is rated at temperatures much
higher than temperature rating of household wiring• The
current carrying capacity of the conductor is governed by
the temperature rating of the insulation around the wire,
rather than the wire gauge alone•
Where local codes permit
connecting
the appliance-
grounding
conductor
to the neutral
(white)
wire
(US Only) (see figure
1):
1. Disconnect the power supply•
2. In the junction box:
connect appliance and power supply cable wires as
shown in Figure 1.
Cable from Power Supply
White Wire
_--_
(Neutral),_
::_z..__..Lk,___
!
_/_Black
-
i
White Wire
Ground Wire j
_
_@
(Neutral)
U.L.-Listed Conduit
(Bare or Green Wire)
>c: _ Connector (or CSA listed)
Cable from appliance
Figure 1
3-WIRE GROUNDED JUNCTION BOX
If oven is used in a new branch circuit
installation
(1996 NEC), mobile
home, recreational
vehicle,
or where
local codes DO NOT permit
grounding
through
the neutral
(white)
wire, the appliance
frame MUST NOT be connected
to the neutral
wire
of the 4-wire
electrical
system. (see figure
2):
1. Disconnect the power supply•
2. Separate the green (or bare copper) and white
appliance cable wires•
3. In the junction box:
connect appliance and power supply cable wires as
shown in Figure 2.
Cable from Power Supply
Ground Wire _
Red
_M_
J'_'_-_/-
White Wire
_WBVB
ir?r_
/
-_ _-:__
White Wire
Junction Box
_::_., -----_-_U.L.-Listed Conduit
_:-::1
Connector (or CSA
listed)
Cable from appliance
Figure 2
4-WIRE GROUNDED JUNCTION BOX
Serial
Plate
Location
You will find the model and serial number printed on the
serial plate• The serial plate is located as shown•
Remember to record the serial number for future