Installation Instructions
Integrated Ventilation System
For use with models: IVS1, IVSR1, IVS2, IVSR2
Part No. 65278 Rev. H

Advertisement

Table of Contents
loading

Summary of Contents for Dacor IVS1

  • Page 1 Installation Instructions Integrated Ventilation System For use with models: IVS1, IVSR1, IVS2, IVSR2 Part No. 65278 Rev. H...
  • Page 2: Table Of Contents

    Dacor Distinctive Service (repairs under warranty only) Phone: (877) 337-3226 (U.S.A. and Canada) Monday — Friday 6:00 . to 4:00 . Pacific Time All specifications subject to change without notice. Dacor assumes no liability for changes to specifications. © 2007 Dacor, all rights reserved.
  • Page 3: Safety Symbols And Labels

    Hazards or unsafe practices that COULD result in severe personal injury or death. • Always contact the Dacor Customer Service Team about problems and conditions that you do not CAUTION understand. Hazards or unsafe practices that COULD result in minor personal injury or property damage.
  • Page 4: General Safety Precautions

    The customer should not install, repair or replace any part of this appliance unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service. Contact the nearest Dacor authorized service representative at (800) 793-0093, or at www.Dacor.com for examination, repair or adjustment.
  • Page 5: Product Specifications

    Product Specifications General Specifications The Dacor Integrated Ventilation System (IVS) is designed Filters Mesh type, dishwasher safe for installation inside custom hood canopies. Proper Lights 120 Vac, 75 Watt, halogen installation of the IVS requires proper selection of the Total Circuit 120 Vac, 60 Hz., 15 Amp.
  • Page 6: Installation Requirements

    • Use only duct work deemed acceptable by state, maximum 7 Amps. (IVS1 and IVS2) or maximum 8 Amps. municipal and local codes. (IVSR1 and IVSR2). •...
  • Page 7 On dual exhaust models, the two 8 inch exhausts may determine the length the duct work cannot exceed, subtract be merged into on 10 inch duct using Dacor transition all of the equivalent lengths of the elbows and transitions ATD10.
  • Page 8: Installation Instructions

    IVS power supply line is turned off at the fuse box or circuit breaker panel. If installing a hood liner (Dacor series IHL) install it • Improper connection of the hood electrical wiring before installing the IVS.
  • Page 9: Verifying Proper Operation

    Distinctive Service at (877) 337-3226. Do not attempt to repair the unit yourself. Be sure to have all model and serial numbers from the product data labels available when you call. Dacor is not responsible for the cost of correcting problems caused by a faulty installation.
  • Page 10: Wiring Diagrams

    Wiring Diagrams NEUTRAL LINE GROUND LAMP DIMMER HALOGEN LIGHTS (2) FAN MOTOR FAN SWITCH IVS1, IVSR1 NEUTRAL LINE GROUND LAMP DIMMER HALOGEN LIGHTS (3) FAN MOTORS FAN SWITCH IVS2, IVSR2...