Installation Instructions Downdraft Vent HRV46, MRV3015S*, MRV36-ERS, MRV3615S*, MRV48-ERS, MRV48S Includes installation instructions for Dacor cabinet blower CABP3, which is an option for the indicated* models. Use these downdraft vents only with approved Dacor appliances. ® See the instructions in this manual to determine suitability with the companion appliance.
Customer Assurance Information If You Need Help... For installation or warranty questions/issues, contact Dacor Customer Assurance. Have available the vent’s model and serial numbers, which are on the data label on the front of the unit. This label includes power-supply requirements.
WARNING • Contact Dacor Customer Assurance about issues and conditions you cannot resolve. (See Customer Hazards or unsafe practices that COULD result in severe Assurance Information.) personal injury or death.
Contact the local building department for details. • Install the vent as instructed in this manual, the Dacor range/ • The electrical outlet for the downdraft vent should be cooktop installation instructions, and the blower installation installed by a licensed electrician.
Installation Specifications Planning the Installation Backsplash General System Layout The vent system consists of the downdraft vent and a Dacor-approved cabinet blower (MRV3015 and MRV3615), Countertop remote blower, or in-line blower. (See Pg. 7). overhang Vertical non-combustible WARNING surface rear wall •...
Page 9
Installation Specifications Backsplash Front of unit Cooktop Cabinet blower option: MRV3015 and MRV3615 Downdraft vent Blower wiring access hole Cabinet blower Connection to option: MRV3015 cabinet blower and MRV3615 Wall only Floor Blower wiring Wall cap Connection to access hole remote/in-line 3 1/4 x 10 blower...
(See Pg. 13). You must install a Dacor blower for the downdraft vent to operate properly. See the blower installation instructions for directions.
Page 11
Installation Specifications 6 1/4" (15.9 cm) 1 1/8" (2.9 cm) Front of unit Motor cover 3” Vertical center line of rear exhaust knock out lines up with vertical center line of chassis ...
Page 13
Installation Specifications Calculating Maximum Duct Run Length Duct Work Design Tips • For best performance, consult a qualified HVAC specialist • Reduce transitions and turns to the fewest sharp angles. when designing the duct system. Two staggered 45° angles are better than one 90°. Keep turns as far from the hood exhaust as possible, with the •...
Installation Instructions Installing the Downdraft Vent in Adapter Installation: CABP3 Blower (Optional: MRV3015S, MRV3615S) the Cutout 1. Remove the front cover so the AERVCAB cabinet 1. Cut a hole in the cabinet so the ducting can to pass to blower adapter can be installed. Remove and retain the the floor/wall for the planned ducting layout.
Installation Instructions Cabinet Blower Installation ILHSF or REMP Series Blower Installation (Optional: MRV3015M/S, MRV3615M/S) If using a ILHSF or REMP series blower, install it according to the blower installation instructions. 1. Find the wiring diagram label included with the adapter kit.
Page 17
Installation Instructions Wires to power plug. Match wire colors to Pre-wired at factory. terminals as shown. Do not modify. Front of unit BLACK WHITE CABP3 cabinet blower Electrical connection Electrical access from downdraft vent, panel match Wire Colors GREEN Attach ground wire Blower power wiring/conduit.
If the downdraft vent fails to function after performing the above checks, do not try to repair it yourself. Contact Dacor Customer Assurance: 833-353-5483. Have available all vent and blower model/serial numbers from the product data labels when you call.