Canon LV S3 - SVGA LCD Projector Specification page 19

Serial functional specification 0.5” svga
Hide thumbs Also See for LV S3 - SVGA LCD Projector:
Table of Contents

Advertisement

8.3.8 "88" [CR]
Status: Normal status after recovering abnormal temperature.
When the temperature goes down after cooling down and moving to Standby
status, this is the response.
This status keeps until the next operation. In short, when Power On is
executed, the temperature information is canceled, and works normal.
8.3.9 "02" [CR]
RS232C Command is unacceptable.
When a computer receives this response, try to execute Status Read Command
again.
8.3.10 "24" [CR]
Status: Processing Power Save•E Cooling Down
When Power Management function is ON in setting menu and there is no signal for
5 minutes, it moves on to Power Save/Cooling Down after tuning off the lamps.
(During this process, Green LED is OFF.)
The control command is invalid
After this Power Save/Coolign Down continues for about 90 seconds, it moves on to
Power Save.•iGreen LED flashes.•j
Status:
No signal
Response "00"?"24"?"04•h
8.3.11 "04" [CR]
Status of Power Save
When the Power Management function is ON in setting menu, and there is no
signal for 5 minutes, it moves on to PowerSave status after PowerSave and Cooling
Down.
Moving on to the status of Power On is the same action as moving on to the Power
On from the status of normal stand by.
•E Power ON Command:"C00"[CR] ¥ ¥ ¥ ¥ ¥ ¥
•E Power OFF Command:"C01"[CR] ¥ ¥ ¥ ¥ ¥
Moving on to the status of Power On is the same action as moving on to the Power
On from the status of normal stand by.
Power Save/Cooling Down
After 5 minutes with no signal
Power Save
after about 90 seconds
¥ ¥ move on the status of power on
move on the status of stand by
Page
19/21

Advertisement

Table of Contents
loading