Download Print this page

Panamax MIW-POWERKIT-MOB Template

Manual

Advertisement

Quick Links

Panamax MIW-MOB
This outlet box is suitable for use with Listed Nonmetallic
Sheath Cable, FMC, AC, or MC.
Expansion
clamp is
used for
retrofit.
One box works in both new and retrofit construction projects.
Features dual-size conduit knockouts (1/2" & 3/4").
STEP 1:
Install the
appropriate conduit/
armored cable into the
knockout hole before
mounting the outlet box.
STEP 2A:
New Construction - The expansion clamps are not used
for new construction; remove them and reposition the
brackets as shown above. Nail or screw the boxes to the
wall studs, run conduit between the 2 locations and attach
it to the boxes.
INS0760 Rev. C
2/05
Panamax MIW-MOB
This outlet box is suitable for use with Listed Nonmetallic
Sheath Cable, FMC, AC, or MC.
Expansion
clamp is
used for
retrofit.
One box works in both new and retrofit construction projects.
Features dual-size conduit knockouts (1/2" & 3/4").
STEP 1:
Install the
appropriate conduit/
armored cable into the
knockout hole before
mounting the outlet box.
STEP 2A:
New Construction - The expansion clamps are not used
for new construction; remove them and reposition the
brackets as shown above. Nail or screw the boxes to the
wall studs, run conduit between the 2 locations and attach
it to the boxes.
INS0760 Rev. C
2/05
STEP 2B:
2b. Retrofit (remodel/old construction) – Using the included template as a guide,
cut holes in the wall. Run the flexible conduit, AC power lines through one of the
openings and route them through the walls to the location of the other box.
Be sure to:
Bracket can be
- Leave enough AC cabling
rotated for use
new construction.
at each end to connect to the
intended equipment. Three
1/2 or 3/4 inch
inches of wire should be able
conduit knockout
to extend beyond the opening
of the outlet box.
Tighten the expansion clamp
screws until the box is held
firmly in place. Be careful not
to over-tighten the expansion
clamps.
www.panamax.com
STEP 2B:
2b. Retrofit (remodel/old construction) – Using the included template as a guide,
cut holes in the wall. Run the flexible conduit, AC power lines through one of the
openings and route them through the walls to the location of the other box.
Be sure to:
Bracket can be
- Leave enough AC cabling
rotated for use
at each end to connect to the
new construction.
intended equipment. Three
inches of wire should be able
1/2 or 3/4 inch
conduit knockout
to extend beyond the opening
of the outlet box.
Tighten the expansion clamp
screws until the box is held
firmly in place. Be careful not
to over-tighten the expansion
clamps.
www.panamax.com
Template for use with
standard switches and
receptacles.
Template for use with
standard switches and
receptacles.

Advertisement

loading

This manual is also suitable for:

Miw-mob