Known Limitations in Junos OS Release 10.4 for SRX Series Services Gateways and J Series Services Routers
Known Limitations in Junos OS Release 10.4 for SRX Series Services Gateways and J Series
Services Routers
Copyright © 2010, Juniper Networks, Inc.
AppSecure
Junos OS application identification—When you create custom application or nested
application signatures for Junos OS application identification, the order value must be
unique among all predefined and custom application signatures. The order value
determines the application matching priority of the application signature.
The order value is set with the
application-name signature order
values by entering the
show services application-identification | display set | match order
command. You will need to change the order number of the custom signature if it
conflicts with another application signature.
Chassis Cluster
On SRX650 devices in a chassis cluster, ping packets sent from the forward node to
the active node are dropped intermittently.
On SRX650 devices in a chassis cluster, the T1/E1 PIC goes offline and does not come
online.
In large chassis cluster configurations on SRX3400 or SRX3600 devices, you need to
increase the wait time before triggering failover. In a full-capacity implementation, we
recommend increasing the wait to 8 seconds by modifying
values in the
heartbeat-interval
The product of the
heartbeat-threshold
before failover. The default values (
of 1000 milliseconds) produce a wait time of 3 seconds.
heartbeat-interval
To change the wait time, modify the option values so that the product equals the
desired setting. For example, setting the
default value for the
heartbeat-interval
seconds. Similarly, setting the
2000 milliseconds also yields a wait time of 8 seconds.
SRX100, SRX210, SRX240, and SRX650 devices have the following chassis cluster
limitations:
Virtual Router Redundancy Protocol (VRRP) is not supported.
In-service software upgrade (ISSU) is not supported.
The 3G dialer interface is not supported.
On SRX Series device failover, access points on the Layer 2 switch reboot and all
wireless clients lose connectivity for 4-6 minutes.
On VDSL mini-PIM, chassis cluster is not supported for VDSL mode.
Queuing on aggregated Ethernet
set services application-identification application
command. You can also view all signature order
hierarchy.
[edit chassis cluster]
and
heartbeat-interval
of 3 beats and
heartbeat-threshold
heartbeat-threshold
(1000 milliseconds) yields a wait time of 8
heartbeat-threshold
to 4 and the
interface is not supported.
(ae)
and
heartbeat-threshold
values defines the time
to 8 and maintaining the
heartbeat-interval
to
133
Need help?
Do you have a question about the JUNOS OS 10.4 - RELEASE NOTES and is the answer not in the manual?
Questions and answers