To remove an alarm panel module or module filler (see Figure 37 on page 100):
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
Pull the release handle to the open position. The module moves out of the bay
2.
approximately 0.25 in. (0.6 cm).
Slide the alarm panel module out of the bay.
3.
Figure 38 on page 101 shows how to remove and install an alarm panel module.