Field Controls 46170300 Installation And Wiring Instructions page 3

Thermal safety switch

Advertisement

WIRING
Refer to System Check-out Procedure Section before operating.
24 VAC S
YSTEMS
CAUTION: Disconnect electrical power when wiring Safety Switch.
1. Remove one of the thermostat wires from the gas control valve and wire the safety switch in series with the
thermostat circuit. (See Diagram A)
2. After installing the safety switch, check the amperage drown through the thermostat circuit and adjust the thermostat
anticipator accordingly.
MILLIVOLT WIRING SYSTEMS
CAUTION: Shut off main gas supply to appliance before wiring.
NOTE: TCA-1 Thermocouple Adapter (Part No. 460827000)
required.
30 M
S
ILLIVOLT
YSTEM
1. Remove thermocouple from gas control valve. (See Figure 5)
2. Thread TCA-1 thermocouple adapter into thermocouple port,
then thread the thermocouple into the bottom of the TCA-1.
(See Figure 6)
3. Connect lead wires (NOTE: 12 GA wire should be used) from the TCA-1
thermocouple adapter to the leads on the thermal switch. (See Diagram B)
750 M
S
ILLIVOLT
YSTEM
Wire the TSP-1 thermal switch in series with one side of the thermostat circuit (See
Diagram C) or pilot generator circuit.
SYSTEM CHECK-OUT PROCEDURE
1. Push the reset on the spillage switch. Light the appliance burner in accordance
with manufacturer's instructions. Operate the appliance to determine that the
appliance will operate continuously.
2. Adjust thermostat so the appliance burner is shut off. Allow system to
cool down, then remove the vent pipe connection near the appliance.
3. Block the appliance vent outlet with a noncombustible material.
4. Adjust thermostat control to call for heat. Allow approximately 2 minutes
for the system flue gases to back up and the gas burner to shut off.
5. Push the reset on the spillage switches, then relight appliance and
perform Steps 3 & 4 again.
6. Re-connect vent pipe connection and cycle system 2 to 3 times to ensure
continuous operation.
NOTE: Shutdown of appliance burner should not be more than 10 minutes.
PRE-INSTALLATION INSPECTION INSTRUCTIONS FOR EXISTING APPLIANCES
R
P
ECOMMENDED
ROCEDURE
C
54, Z223.1 A
ODE
PPENDIX
The following procedure is intended as a guide to aid in determining that an appliance is properly installed and is in a safe
condition for continuing use. This procedure is predicated, on central furnace and boiler installations, and it should be
F
S
I
OR
AFETY
NSPECTION
H:
O
A
E
A
F
N
XISTING
PPLIANCE
Page 3
Diagram A
Figure 5
I
B
T
N
NSTALLATION
Y
HE
ATIONAL
Figure 6
Diagram B
Diagram C
F
G
UEL
AS

Advertisement

loading