Water System
Symptom
Pulsating jets
No Jet Action, or action is poor
3 Flashing Lights
Symptom
28
Aquatic Fitness System
Troubleshooting Guide
Problem
Water level too low
1.
HydroTherapy Jets closed
2.
Diverter Valve turned
3.
Dirty Filter
4.
Air lock
5.
Gate valve closed
Problem
High Temperature Protection:
If the water temperature exceeds 112°F at
the Temperature Sensor, the heater and all
other outputs will shut off.
If the water temperature exceeds 119°F at
the Hi-Limit Sensor, only the heater will be
shut off. All other outputs will continue to
operate.
After the water has cooled down, power to
the Aquatic Fitness System must be cycled
on, then off, to reset the system.
Smart Winter Mode:
If the system detects conditions below
59°F, the system will automatically activate
the Smart Winter Mode for a period of 24
hours. In this mode, if a pump has not
been powered up in the last two hours, the
system will turn it on for one minute to
prevent freezing. The Filter Mode Light
indicator will flash while the pump is
running in this mode.
If the spa water temperature drops below
49°F, the pump and heater will be turned
on for a period of 2 minutes, or until the
water reaches 50°F. All functions (except
the alarms) will be disabled while the freeze
protection is active.
Temperature Sensors:
If 33°F appears constantly on the display, or
if the temperature displayed greatly differs
from the actual temperature of the water,
your temperature sensor may be in need of
service.
Corrective Action
Fill with water to 1" to 2" above bottom of
the tile line
1.
Open Jets
2.
Turn the Diverter Valve clockwise or
counter clockwise
3.
Clean Filter
4.
Loosen pump union to allow air to
escape
5.
Open gate valve
Corrective Action
If the temperature fails to drop, or the
heater or other outputs fail to stop as
indicated, call the dealer.
If the temperature does not
seem to be elevated, the error
indication may have been
caused by poor water flow or
electrical line interference
(thunder storms, voltage
surges, etc.) Simply reset and
monitor the system.
No action necessary, unless the water
temperature continues to drop and the
systems fails to activate. If this happens, you
should manually activate the heater and
pumps, if freezing could be a problem, then
call the dealer for service.
If you notice your pumps
coming on every 2 hours, this
is most likely the cause. This
will continue for a 24-hour
period. This is normal and is
the Systems protection against
freezing.
Call the dealer for service.