Download Print this page

TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8500402 REV B 0803 Manual

Hide thumbs Also See for PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8500402 REV B 0803:

Advertisement

Quick Links

Insufficient combustion air causes:
Flue gas spillage, flame roll-outs, decreased
efficiencies, and reduced heating equipment life.
Conventional metal louvers
often are a major cause of
these problems:
Unregulated outdoor air supply
that changes with temperatures,
speed and direction of winds.
Architecturally unsightly large
outside wall openings that often
require structural reinforcement.
Mechanical room freeze ups in
northern climates.
Often not compatible with below grade or
interior mechanical rooms.
Tjernlund In-Forcer combustion air intakes
are packaged systems engineered to provide
controlled, interlocked combustion air.
Wall or roof opening size can be reduced by up
to 80% compared to conventional metal louvers.
In-Forcers include
matching, low profile
intake hoods that can
be mounted on either
a roof or sidewall.
Use small diameter
duct to deliver out-
door air up to 100 feet
away from intake hood.
Complies with Mechanical
Code requirements for combustion air supply.

Advertisement

loading
Need help?

Need help?

Do you have a question about the PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8500402 REV B 0803 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TJERNLUND PAI-3,4,5,6,7 COMMERCIAL COMBUSTION AIR IN-FORCERS 8500402 REV B 0803

  • Page 1 Insufficient combustion air causes: Tjernlund In-Forcer combustion air intakes Flue gas spillage, flame roll-outs, decreased are packaged systems engineered to provide efficiencies, and reduced heating equipment life. controlled, interlocked combustion air. Wall or roof opening size can be reduced by up Conventional metal louvers to 80% compared to conventional metal louvers.
  • Page 2 The original and most practical alternative to metal louvers BY TJERNLUND Use in virtually all mechanical room locations The IN-FORCER can be ducted up to 100 equivalent feet from the intake hood. Even isolated mechanical rooms can easily be supplied with outdoor combustion air.
  • Page 3 The UC1 Universal Control is the the A – B dry contacts. The Linear standardized interlock control for Limit switch disables the heater in Tjernlund Draft/Ventilation products. the event of a venting malfunction. The UC1 includes adjustable pre/post Includes JA1 thermocouple junction purge and LED status/diagnostic adapter.
  • Page 4 Not Applicable 3,400,000 3,500,000 3,600,000 3,700,000 Multiple IN-FORCERS may be installed for capacities larger than shown on chart. Tjernlund UB-Series Universal Blowers are available for larger capacity applications. UB-Series Fans Also Available DIMENSIONS (in inches) FRONT VIEW SIDE VIEW UNIT SIZE DIA.