Issues Fixed
581912
590171
581698
572619
583775
563886
580749
586957
6
Novell Sentinel Log Manager 1.0.0.5 Release Notes
Description
Issue: Upgrading to Hot Fix 4 fails on a remote 64 bit Linux Collector
Manager.
Fixed: The installer now checks for the directory name. The upgrade
procedure now works fine.
Issue: The All Vendors All Products Top 10 Report is not installed when
user upgrades to Hot fix 4 from versions older than Hot Fix 3.
Fixed: The report is now installed.
Issue: The
start_tomcat.sh
address to write to JNLP files on startup.
Fixed: The script now attempts to read the user specified SERVER_IP
value from the
ipaddress.conf
present or if the IP address is not set in the file, then the script determines
the IP address automatically.
To enable the script to read the SERVER_IP value from the configuration
file, create the
ipaddress.conf
directory and specify the IP address in the following format:
SERVER_IP=<ip address value>
For example,
SERVER_IP=192.168.1.255
Issue: Attempt to download raw data files for an Event Source which has a
name with double byte characters results in the
java.io.FileNotFoundException
Fixed: Users can now download raw data files with double byte characters
in their names.
Issue: A non-admin user is allowed to click the Get Raw Data link in their
search results. This links should be presented only to administrators.
Fixed: Now, when a non-admin user clicks the Get Raw Data link, the
following error message is displayed in the resulting page:
Must be an Administrator to download Raw Data
Issue: The Collector framework must stop overwriting event fields so that
the Sentinel Link can properly report the agent that parsed the event.
Fixed: The Collector framework now doesn't overwrite the event fields
other than the rv21-rv25 fields.
Issue: If you click the Help button from Web UI, an error page is displayed.
This is because an extra / is added to the URL.
Fixed: This issue is now fixed. If you click the Help button, the Novell
Sentinel Log Manager documentation page opens.
Issue: Clicking details+ in Web UI fails for the events from a Collector that
does not populate the rv32 field.
Fixed: Clicking details+ in Web UI now expands even for events with
empty rv32 field.
script is unable to find the correct IP
file. If the
ipaddress.conf
file in the
$ESEC_HOME/config
error.
file is not
Need help?
Do you have a question about the SENTINEL LOG MANAGER 1.0.0.5 - RELEASE NOTES and is the answer not in the manual?