Download Print this page

Slee MTR Operating Manual

Bench top quick-freezing unit
Hide thumbs Also See for MTR:

Advertisement

Quick Links

O P E R A T I N G
M A N U A L
M T R
BENCH TOP QUICK-FREEZING UNIT
D ES I GN &
M A N UFACT UR I N G
M A D E I N GE R M A NY

Advertisement

loading
Need help?

Need help?

Do you have a question about the MTR and is the answer not in the manual?

Questions and answers

Summary of Contents for Slee MTR

  • Page 1 O P E R A T I N G M A N U A L M T R BENCH TOP QUICK-FREEZING UNIT D ES I GN & M A N UFACT UR I N G M A D E I N GE R M A NY...
  • Page 2 Manual_MTR_2025-03-013.00_EN.docx...
  • Page 3 The information, numerical data and notes contained in this document represent the current state of scientific knowledge and state-of-the-art technol- ogy as we understand it following thorough investigation in this field. SLEE medical GmbH is under no obligation to update the present manual periodi- cally and on an ongoing basis according to the latest technical developments, nor to provide our customers with additional copies, updates etc.
  • Page 4 Manual_MTR_2025-03-013.00_EN.docx...
  • Page 5 OPERATION OF THE MTR _____________________________________________ 12 MOUNTING THE COOLING BLOCK ON THE CUT SERIES MOUNTING THE COOLING BLOCK ON THE SLIDING MICROTOME STANDARD ACCESSORIES MOUNTING THE MTR ON THE SLIDING MICROTOME PROGRAMMING THE MTR FIXING THE SAMPLE DEFROSTING THE COOLING BLOCK...
  • Page 6 Manual_MTR_2025-03-013.00_EN.docx...
  • Page 7 Combined with the standard specimen clamp*, the cooling block cools down to -45 °C. In case of high ambient humidity, there is a possibility of ice formation on the cooling block. In this case, the MTR provides a manual defrost function.
  • Page 8 3 OVERVIEW DEVICE Picture: MTR for use in combination with Cuttec S (incl. pillar) Manual_MTR_2025-03-013.00_EN.docx...
  • Page 9 4 SAFETY NOTES The Slee bench top quick-freezing units are provided with the following safety features: Self-optimized controller for temperature accuracy • Manual defrost • The institution which owns the unit and the persons working with the unit, servicing or repairing it have the responsibility for a hazard-free use.
  • Page 10 Cylinder screw ISO 4762 - M8 x 60 - A2 • Manual • • *The pillar is only included with MTR for Cuttec S! 6 SPECIFICATIONS Operating temperature range +10 to +35 °C Operating humidity max. rel. 80 %, non-condensing Storage temperature range +5 to +55 °C...
  • Page 11 7 UNPACKING AND INSTALLATION UNPACKING THE DEVICE Open the wooden box and remove the supporting foam. Lift the device out of the wooden transportation case. Keep the packaging material in case of later transport purposes, as the device should be transported in the original packaging to avoid transportation damage.
  • Page 12 8.1 MOUNTING THE COOLING BLOCK ON THE CUT SERIES The MTR cooling head with screwed-on insulation element is already pre-assembled. It can be positioned centrally in the standard object clamp. In order to ensure a permanently secure connection, the knurled screw should be hand-tightened with a 17 mm open-ended wrench*.
  • Page 13 To ensure a permanently secure connection, the knurled screw should be hand-tightened with a 17 mm open-end wrench*. In order to be able to use the MTR in the optimum cutting range with the Cuttec S, different interme- diate plates according to need must be mounted.
  • Page 14 70010860 8.4 PROGRAMMING THE MTR The MTR has a central operating panel with display. The display shows two different temperatures whereat the upper line states the actual temperature and the line below shoes the programmed temperature configured by the user.
  • Page 15 Depending on the configured temperature and the ambient conditions (humidity), ice may build up at the cooling block. The MTR features a defrost function allowing the user to actively melt the ice by pressing the defrost button (see display). After the ice has melted, press the defrost button again to stop the defrosting process.
  • Page 16 Do not spray or use cleaning agents directly on the display. 10 OPTIONAL ACCESSORIES Normally, the MTR quick-freezing unit does not require any further accessories. If you still need accessories, please contact your Slee service technician. Manual_MTR_2025-03-013.00_EN.docx...
  • Page 17 If it is necessary to return the device, it must be cleaned and disinfected before delivery. It must be returned in its original packing. If the device or parts thereof are sent back in a dirty or non-disinfected condition, SLEE medical GmbH reserves the right to return the parts to the debit of the customer.
  • Page 18 Notes Manual_MTR_2025-03-013.00_EN.docx...
  • Page 19 Manual_MTR_2025-03-013.00_EN.docx...
  • Page 20 SLEE medical GmbH • Am Neuberg 14 55268 Nieder-Olm • Germany www.slee.de T: +49 (0) 6136 76997-0 E: mail@slee.de www.slee.de YouTube LinkedIn Instagram Manual_MTR_2025-03-013.00_EN...