Hans Grohe Aquno Select M81 250 2jet 73836 7 Series Instructions For Use/Assembly Instructions
Hans Grohe Aquno Select M81 250 2jet 73836 7 Series Instructions For Use/Assembly Instructions

Hans Grohe Aquno Select M81 250 2jet 73836 7 Series Instructions For Use/Assembly Instructions

Hide thumbs Also See for Aquno Select M81 250 2jet 73836 7 Series:

Advertisement

ZH 用户手册 ⁄ 组装说明
EN Instructions for use ⁄ Assembly instructions
2
3
Aquno Select M81 250 2jet
Aquno Select M81 170 3jet
73836XX7
73837XX7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aquno Select M81 250 2jet 73836 7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hans Grohe Aquno Select M81 250 2jet 73836 7 Series

  • Page 1 ZH 用户手册 ⁄ 组装说明 EN Instructions for use ⁄ Assembly instructions Aquno Select M81 250 2jet 73836XX7 Aquno Select M81 170 3jet 73837XX7...
  • Page 2 中文 符号说明 安全技巧 请勿使用含有乙酸的硅胶! 装配时为避免挤压和切割受伤,必须戴上手 套。 调节 (参见第页 9) 冷热水管间过大的压力差必须予以平衡。 热水温度调节。如果使用即热式喷头,则不建议 安装提示 安装热水阀门。 • 安装前必须检查产品是否受到运输损害。 安装 保养 (参见第页 11) 后将不认可运输损害或表面损伤。 • 管道和阀门必须根据通用标准进行安装、冲洗 单向阀必须在符合国家或当地的法律的情况下按 和检查。 照EN 806-5定期检查 (至少一年一次) 。 • 请遵守当地国家现行的安装规定。 大小 (参见第页 18) 技术参数 流量示意图 (参见第页 18) 0,8 MPa 工作压强: 最大 0,1 - 0,5 MPa 推荐工作压强: 备用零件 (参见第页 12) 1,6 MPa 测试压强: (1 MPa = 10 bar = 147 PSI) XX = 颜色代码 60°C 热水温度:...
  • Page 3: Safety Notes

    English Symbol description Safety Notes Do not use silicone containing acetic acid! Gloves should be worn during installation to prevent crushing and cutting injuries. Adjustment (see page 9) The hot and cold supplies must be of equal To adjust the hot water limiter. Using a hot water limiter pressures. in combination with a continuous flow water heater is Installation Instructions not recommended. • Prior to installation, inspect the product for transport Maintenance (see page 11) damages. After it has been installed, no transport or surface damage will be honoured. The check valves must be checked regularly according • The pipes and the fixture must be installed, flushed to EN 806-5 in accordance with national or regional and tested as per the applicable standards. regulations (at least once a year). • The plumbing codes applicable in the respective Dimensions (see page 18) countries must be observed. Flow diagram (see page 18) Technical Data Operating pressure: max. 0,8 MPa Spare parts (see page 12) Recommended operating pressure: 0,1 - 0,5 MPa XX = Colors...
  • Page 4 (3 Nm) (3 Nm) SW 10 mm SW 24 mm (4 Nm) 1. SW 19 mm (4 Nm) 150° 60° 110°...
  • Page 5 150° 75° 75° 24 x 15° 105° 45° 105° 45°...
  • Page 6 110° 55° 55° 110° 24 x 15° 85° 25° 85° 25°...
  • Page 7 60° 30° 30° 60° 24 x 15° 45° 15° 45° 15°...
  • Page 8 Armaturenfett Grease 滑油 CLICK...
  • Page 9 60 °C 10 °C 0,3 MPa SW 3 mm 60°C 36°C 55°C 38°C 50°C 43°C SW 3 mm (5 Nm)
  • Page 10 开 / open 关 / close 热 / hot 冷 / cold Aquno Select M81 170 3jet 73837XX7...
  • Page 12 Aquno Select M81 250 2jet 73836XX7 40963000 98112000 (8x2) 93749XX0 96456000 93751XX0 (150°/110°/60°) 93748000 98426000 (19x2) 93750000 93776XX0 98365000 92926000 93183000 93782000 92491000 93781XX0 93841000 (M4x12) 97827000 93558000 98170000 (8x1,75) (10x2) 93777XX0 97827000 97523000 (8x1,75) 92914000 97548000 (400 mm) 95049000 93780000 92500000 (900 mm) 93816000...
  • Page 13 Aquno Select M81 170 3jet 73837XX7 40963000 98112000 (8x2) 93749XX0 96456000 (150°/110°/60°) 93778XX0 95910000 98426000 (19x2) 93342XX0 93776XX0 98365000 92926000 93183000 93782000 92491000 93781XX0 93841000 (M4x12) 97827000 93558000 98170000 (8x1,75) (10x2) 93777XX0 97827000 97523000 (8x1,75) 92914000 97548000 (400 mm) 95049000 93780000 92500000 (900 mm) 93816000...
  • Page 14 • • • • Hansgrohe • Hansgrohe • www.hansgrohe-int.com/guarantee • • QuickClean • QuickClean • • QUICK QUICK CLEAN CLEAN...
  • Page 15: Warranty

    English Cleaning Recommendation for Hans- • After cleaning rinse thoroughly with clean water to remove any cleaner residue. grohe Products • The use of steam cleaners is not permitted. The high Today, modern sanitary and kitchen tapware, showers, temperatures can damage the products. accessories, washstands, tubs and radiators consist of Important very different materials to comply with the needs of the...
  • Page 16 SW 2 mm SW 2 mm (0,6 Nm)
  • Page 17 SW 12 mm SW 24 mm...
  • Page 18 Aquno Select M81 250 2jet 73836XX7 m a x . 5 0 Ø 14 4 19 0 4 2 6 Ø 3 4 2 2 4 4 0 0 G 3 / 8 G1/2 0,60 0,55 0,50 0,45 0,40 0,35 0,30 0,25 0,20...
  • Page 19 Aquno Select M81 170 3jet 73837XX7 m a x . 5 0 Ø 14 4 19 0 2 2 0 4 2 6 2 3 4 4 0 0 G 3 / 8 G 3 / 8 G1/2 0,60 0,55 0,50 0,45 0,40...
  • Page 20 Hansgrohe · Auestraße 5 - 9 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440 E-Mail: info@hansgrohe.com · Internet: www.hansgrohe.com...

This manual is also suitable for:

Aquno select m81 170 3jet 73837 7 series

Table of Contents