Fanimation COVERT LP8359LAZ Manual
Fanimation COVERT LP8359LAZ Manual

Fanimation COVERT LP8359LAZ Manual

Advertisement

Quick Links

ATTACH YOUR RECEIPT HERE
READ AND SAVE THESE INSTRUCTIONS
Serial Number
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-888-567-2055, 8 a.m.-5 p.m., EST, Monday-Friday.
Purchase Date
COVERT
CEILING FAN
MODEL #LP8359LAZ
Net Weight 22.33 lbs (10.13 kg)
Español p. 20
ITEM #0588962

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the COVERT LP8359LAZ and is the answer not in the manual?

Questions and answers

Summary of Contents for Fanimation COVERT LP8359LAZ

  • Page 1 COVERT CEILING FAN ™ MODEL #LP8359LAZ Español p. 20 ITEM #0588962 ATTACH YOUR RECEIPT HERE READ AND SAVE THESE INSTRUCTIONS Serial Number Purchase Date Net Weight 22.33 lbs (10.13 kg) Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-888-567-2055, 8 a.m.-5 p.m., EST, Monday-Friday.
  • Page 2: Important Safety Instructions

    6. All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan or Fanimation. 7. Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.
  • Page 3: Table Of Contents

    Fanimation will not be responsible for any damage resulting from improper packaging. 9. It is understood that any repair or replacement is the exclusive remedy available from Fanimation. There is no other expressed or implied warranty. Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law.
  • Page 4: Tools Needed For Assembly

    Light Kit Assembly With Glass product by Fanimation. Substitution of parts or accessories not designated for use with this product LED Assembly by Fanimation could result in personal injury or property damage. teel Cap and eld e ote 1. Check to see that you have received the following parts: NOTE: If you are uncertain of part description, refer to exploded view illustration.
  • Page 5: Energy Efficient Use Of Ceiling Fans

    8 - 9 feet above the floor for optimal airflow. Consult your down into the occupied space.Remember to adjust your Fanimation Retailer for optional mounting accessories. thermostat when using your ceiling fan - additional energy and dollar savings could be realized with this simple step! Turn Off When Not in the Room Ceiling fans cool people, not rooms.
  • Page 6 Electrical and Structural Requirements (Continued) Brace use (Figure 3) Paired with a deep box, this hanger is meant to span CEILING JOIST between two joists and takes the place of wooden blocking. WARNING To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked acceptable for fan support of 15.88 kg (35 lbs) or less.
  • Page 7: How To Assemble Your Ceiling Fan Blades

    How to Assemble Your Ceiling Fan Blades 1. Disassemble the upper housing cover by removing the six screws at the top of the motor assembly and retain for Step 3. Carefully twist and lift off the cover. Upper Housing (Figure 1) Cover Figure 1 2.
  • Page 8 How to Assemble Your Ceiling Fan (continued) 3. Loosen the two set screws and locking nuts in Black and White the downrod support of the motor assembly. Route Wires the black and white wires through the downrod. (Figure 3) Downrod Set Screws (2) Figure 3 4.
  • Page 9: How To Hang Your Ceiling Fan

    How to Hang Your Ceiling Fan WARNING To avoid possible re or shock, be sure electricity is turned off at the main fuse box before hanging. MAIN FUSE BOX (Figure 1) NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be Figure 1 grounded for safe operation.
  • Page 10: How To Wire Your Ceiling Fan

    How to Wire Your Ceiling Fan WARNING To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before hanging MAIN FUSE BOX (Figure 1). NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as Figure 1 it must be grounded for safe operation.
  • Page 11: How To Install Your Canopy Housing

    How to Install Your Canopy Housing NOTE: This step is applicable after the neccessary wiring is completed. Remove one of the two shoulder screws in the hanger bracket. Loosen the second shoulder screw without fully removing it. Assemble canopy by rotating key slot in canopy over shoulder screw in hanger bracket.
  • Page 12: How To Operate Your Ceiling Fan

    How to Assemble Your Light Kit Assembly or Cap (continued) 4. Assemble the LED assembly to the light assembly use the removed screws in Step 2. (Figure 4) CAUTION Light Kit The light source is designed for this specific Assembly application and can overheat if serviced by untrained personnel.
  • Page 13 How to Operate Your Ceiling Fan (continued) 3. To make fan operational, install 3V battery (included) in hand-held remote transmitter, with fan power off. Then follow the remote code setting process. (If not used for long periods of time, remove battery to 3V, CR2032 prevent damage to transmitter).
  • Page 14: How To Install Your Remote Control

    How to Operate Your Ceiling Fan (continued) 6. “D” and “O” dip switch: For this fan, switch should be in the "D" position, allowing for dimming of the light. (Figure 6) The receiver provides the following protective function: Lock position: The DC motor has a built-in safety feature against blade obstruction against obstruction during operation.
  • Page 15: Trouble Shooting

    5. Fan blades out of balance. 5. Balance blades using balance kit provided in hardware bag. 4.NOT ENOUGH AIR 1. If possible, consider using a longer MOVEMENT downrod (not included, you can buy the longer downrod from fanimation.com).
  • Page 16: Parts List

    Parts List Model No. LP8359LAZ Reference # Description Part # APP799004BL Hanger Bracket Assembly ADRAC4GT1-45LAZ Hanger Ball/Downrod Assembly Canopy P835901LAZ APPCP1101BL Canopy Screw Cover Assembly Motor Coupling Cover AP835902LAZ Fan Motor Assembly AMA8359LAZ Blade Set AP835905DWA Light Kit Assembly with Glass AP835907LAZ AP835910 LED Assembly...
  • Page 17: Exploded-View Illustration

    Covert ™ Model LP8359LAZ Exploded-View Illustration Figure 1 NOTE: The illustration shown is not to scale or its actual con guration may vary. Product/parts are subject to change without notice.
  • Page 19 10983 Bennett Parkway Zionsville, IN 46077 Phone: 888-567-2055 Outside U.S.: 317-733-4113 2016/01 V.01 FAX: 866-482-5215 Copyright 2016 Fanimation www.fanimation.com...
  • Page 20 VENTILADOR DE TECHO COVERT ™ MODEL #LP8359LAZ ARTÍCULO #0588962 Adjunte su recibo AQUÍ LEA Y GUARDE ESTAS INSTRUCCIONES Número de serie Fecha de compra Peso neto 10.13 kg (22.33 lbs) Preguntas, problemas, piezas faltantes? Antes de volver a la tienda, llame a nuestro Departamento de Servicio al Cliente al 1-888-567-2055, 8 a.m.
  • Page 21: Instrucciones De Seguridad Importantes

    GARANTÍA LIMITADA DE POR VIDA DEL MOTOR - Si se produjera una falla en alguna de las partes del motor de su ventilador debido a un defecto en los materiales o en la fabricación durante el tiempo de vida del comprador original, Fanimation proporcionará la pieza de repuesto sin cargo una vez que el ventilador defectuoso sea devuelto a nuestro centro de servicios nacional.
  • Page 22 En ningún caso se podrá devolver un ventilador sin previa autorización por parte de Fanimation. Las devoluciones autorizadas deberán ir acompañadas del recibo de venta y deberán enviarse a Fanimation, previo pago del flete. El ventilador que se devuelva deberá estar embalado en forma adecuada a fin de evitar daños durante el transporte. Fanimation no se hará responsable de los daños que resulten del embalaje incorrecto del producto.
  • Page 23: Instrucciones Para El Desempaque

    – Conectores de cables para el mismo. La sustitución de piezas o accesorios no con el vidrio designados por Fanimation para usar con este producto podría ocasionar lesiones personales o daños en el ventilador. Póngase en contacto con su tienda si faltan piezas o hay piezas dañadas.
  • Page 24: Requisitos Eléctricos Y Estructurales

    óptimo. del reloj. Esto produce una suave corriente ascendente, Consulte en su tienda minorista de Fanimation para que obliga al aire cálido que se acumula cerca del techo a obtener accesorios de montaje opcionales.
  • Page 25 Requisitos eléctricos y estructurales (cont.) Uso del soporte (Figura 3) Vigas del Conectado a una caja de distribución eléctrica, este colgador techo sirve para abarcar el espacio entre dos vigas y ocupar el lugar de bloqueo de la madera. ADVERTENCIA Para reducir el riesgo de incendios, descargas eléctricas o lesiones personales, fije el ventilador a la caja de distribución eléctrica marcada como aceptable para...
  • Page 26: Cómo Ensamblar El Ventilador De Techo

    Cómo ensamblar las aspas de techo 1. Desmonte la carcasa de la cubierta superior extrayendo los seis tornillos ubicados en la parte superior de la unidad del motor y guárdelos para el paso 3. Carcasa de la Gírela cuidadosamente y levante la carcasa. (Figura 1) cubierta superior Figura 1 2.
  • Page 27 Cómo ensamblar el ventilador de techo (cont.) Afloje los dos tornillos de fijación del soporte del Negro y Blanco cables barral Introduzca los cables de color negro y blanco de soporte para techo a través de la varilla. (Figura 3) Bola para colgar Tornillo de fijación (2)
  • Page 28: Cómo Colgar El Ventilador De Techo

    Cómo colgar el ventilador de techo ADVERTENCIA Para evitar una posible descarga eléctrica, asegúrese de cortar la alimentación eléctrica de la caja de PRINCIPAL CAJA DE fusibles principal antes de colgar el ventilador. FUSIBLES (Figura 1) NOTA: Si no está seguro de si la caja de salida tiene Figura 1 conexión a tierra, pida consejo a un electricista certificado, ya que debe tener conexión a tierra para...
  • Page 29: Cómo Realizar La Instalación Eléctrica Del Ventilador De Techo

    Cómo realizar la instalación eléctrica del ventilador de techo ADVERTENCIA Para evitar una posible descarga eléctrica, asegúrese de cortar la alimentación eléctrica de la caja de fusibles PRINCIPAL CAJA DE principal antes de colgar el ventilador. (Figura 1) FUSIBLES NOTA: Si no está seguro de si la caja de salida tiene conexión a tierra, pida consejo a un electricista certificado, ya que debe tener conexión a tierra para un funcionamiento Figura 1...
  • Page 30: Cómo Instalar La Carcasa De La Cubierta

    Cómo instalar la carcasa de la cubierta NOTA: Este paso se debe realizar luego de completar lacompleted. instalación eléctrica necesaria. 1. Extraiga una de los tornillos de hombro en el soporte del gancho. Afloje el segundo tornillo de hombro sin extraiga completamente.
  • Page 31: Cómo Utilizar Su Ventilador De Techo

    Cómo ensamblar su el kit de iluminación o la tapa (cont.) Instale la unidad LED en la unidad del kit de iluminación usando los tornillos extraídos en el paso 2. (Figura 4) PRECAUCIÓN Ensamble La fuente de luz está diseñado para esta aplicación de kit de luz específica y puede recalentarse si reparado por Unidad de...
  • Page 32 Cómo utilizar su ventilador de techo (Cont.) 3. Para que el ventilador sea functional, instale las pilas (incluidas) de 23A/12V en el transmisor del mando a distancia. Mientras el ventilador esté apagado. A 3V, CR2032 continuación, siga el proceso de fijación remota de código. BATTERY Si no se utiliza el ventilador durante un largo periodo 3V CR2032...
  • Page 33: Cómo Instalar Su Mando A Distancia

    Cómo utilizar su ventilador de techo (Cont.) Posición de bloqueo: El motor CC posee una función de seguridad integrada para evitar la obstrucción de las palas durante el funcionamiento del ventilador. Si algo obstruyera las palas del ventilador, el motor dejaría de funcionar tas 30 segundos de interrupción.
  • Page 34: Solución De Problemas

    4. NO HAY SUFICIENTE 1. Si es posible, considere el uso de un barral más largo. Por ejemplo (no incluido, usted puede comprar el MOVIMIENTO DE AIRE tiempo de la vara hacia abajo fanimation.com)
  • Page 35: Lista De Piezas

    Lista de piezas Modelos N .° LP8359LAZ Descripción Pieza # N.° N.° de Ref. APP799004BL Unidad del soporte de suspensión ADRAC4GT1-45LAZ Unidad del barral/de la semiesfera Capuchón de techo P835901LAZ APPCP1101BL Cubierta para el tornillo del capuchón Cubierta de unión del motor AP835902LAZ Unidad del motor del ventilador AMA8359LAZ...
  • Page 36: Ilustración Del Despiece

    Covert ™ Modelo N.º LP8359LAZ Ilustración del despiece Figura 1 NOTA:...
  • Page 38 10983 Bennett Parkway Zionsville, IN 46077 Llame Sin Cargo al: 888-567-2055 Desde fuera de los EE.UU. llame al : 317-733-4113 2016/01 V.01 FAX: 866-482-5215 Copyright 2016 Fanimation www.fanimation.com...

Table of Contents