For the earliest warning, we recommend this CO alarm is fitted in a room where the temperature is between -10°C (14°F) and 40°C (104°F).
Usage outside the temperatures stated above will reduce product life.
This CO alarm is suitable for use in domestic premises (caravan holiday homes), caravans, motor caravans and boats.
This alarm must be installed by a competent person, able to install according to the instructions. Please keep this user
manual in a safe place.
Technical Support
Online: www.fireangeltech.com/support
E-mail: technicalsupport@fireangeltech.com
Phone: 0330 094 5830
Fire & Rescue Customers: 0800 141 2561
www.fireangeltech.com
© FireAngel Safety Technology Limited, Vanguard Centre, Coventry CV4 7EZ, UK
Note: This user manual is also available in large text and other formats. Please email:
technicalsupport@fireangeltech.com or call 0330 094 5830 for further information
FA3313, FA3322, FA3328 & FA3820
TEST YOUR ALARM
MONTHLY
®
BS EN 50291-1: 2018
EN 50291-2: 2019
KM551504
GN5672R3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FA3313 and is the answer not in the manual?

Questions and answers

Summary of Contents for FireAngel FA3313

  • Page 1 The original English version of the manual, from which these translations were taken, has been independently approved. In case of discrepancy with translated parts, FireAngel Safety Technology Limited confirms that the English guide is true and correct. For the earliest warning, we recommend this CO alarm is fitted in a room where the temperature is between -10°C (14°F) and 40°C (104°F).
  • Page 2 1. POSITIONING In which room should the alarm be installed? Your carbon monoxide (CO) alarm is suitable for the landing, hallway, bedroom, living room, dining room and kitchen. Common sources of CO include: oil and gas boilers, portable generators, oil or solid fuel cookers, gas or paraffin heaters, barbecues, clogged chimneys, wood or gas fireplaces, any gas or fossil fuel-burning appliance and even adjoining properties.
  • Page 3 Where in the room should I place the alarm? Alarms located in the same room as a fuel-burning appliance should be: • at a horizontal distance of between 1m – 3m from the potential source. • located on the same side of a partition as the potential source. •...
  • Page 4: Installation

    NOTE: The FA3328 CO alarm will not operate unless its base plate is attached. FA3328 is supplied with an optional anti-tamper lock. To activate If you are travelling or storing your alarm, CO alarms FA3313, FA3322 and FA3820 can be deactivated by refitting the disabling ed by pressing the Test / button.
  • Page 5: Alarm Silence

    NOTE: The FA3322 CO alarm will not sound the Extreme Temperature warning when Sleep detect a CO leak. Easy mode is engaged. marking on the alarm. VENTILATE & EVACUATE FireAngel Safety Technology Limited. Email: (UK) technicalsupport@fireangeltech.com, (DE) technik@fireangeltech.com, (FR) supporttechnique@fireangeltech.com, (NL) klantenservice@fireangeltech.com, (INT) Internationalsupport@fireangeltech.com...
  • Page 6 (identified by the until the CO level has reduced to below 50ppm. on on the FA3313, FA3328 & FA3820, or when using the FA3322). After which the device will flash the red...
  • Page 7: Maintenance

    4. MAINTENANCE Test the alarm every month. Press the Test button. The alarm will sound. If the alarm does not sound, contact Technical Support. NOTE: The above method fully tests all elements of the alarm. Additional but not essential testing may be conducted using the Sense-CO Test mode and CO gas.
  • Page 8: System Status Indicators

    Your CO alarm constantly checks the accuracy of its sensor and circuitry. All alarms must indicate when there is a fault or if the battery power is low (identified by the icon on the FA3313, FA3328 & FA3820, or when using the FA3322).
  • Page 9 The alarm will silence for 8 hours and the amber LED will continue to flash. NOTE: You can silence your device a maximum of 10 times. • If your alarm is an FA3313 and is signalling low batteries, replace the batteries as soon as possible.
  • Page 10 7. FA3322 LCD SCREEN INDICATORS The multi-feature FA3322 operates as a CO alarm and an extreme temperature alarm. In stand-by mode, the device indicates the room temperature and automatically detects nighttime hours in order to reduce any frustrating interruptions during sleep. The FA3322 alarm LCD screen has many icons with one or more being shown at any one time.
  • Page 11 Sync-It offers immediate, digital access to FA3328 alarm diagnostics via your phone or tablet. It uses the NFC (Near Field Communication) technology available on most mobile devices. 1. Use the QR code to download the FireAngel app or visit www.fireangeltech.com/sync-it 2. Tap your phone on the device where you see the icon.
  • Page 12 Signale aus: 3.2. Alarmdeaktivierung stummgeschaltet und nach vier Tagen zurückge- Modelle FA3313, FA3322, FA3328 und FA3820 gilt für den es einrastet. • auf derselben Seite einer Trennwand wie die mög- • Niedriger Batteriestand: 1 Piepser/min und 1 gel- setzt.
  • Page 13 FireAngel Safety Technology Limited will not recognise any changes to this warranty by third parties. For FA3313, this warranty does not cover replaceable batteries which are Übelkeit), und weisen Sie darauf hin, dass Sie eine considered user-replaceable parts.
  • Page 14 Celsius mit einer Genauigkeit von +/- 0.5 ºC an. disabling tab is no longer available, then the Beträgt die CO-Konzentration weniger als 10 ppm, clip can be replicated. For FA3313, once the zeigt das Gerät ALL CLEAR an. batteries are removed, the low battery warning CO­Warnmelder...

This manual is also suitable for:

Fa3322Fa3328Fa3820

Table of Contents