Model: 10003259 00001
-en-
Status: 08.04.2024

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ELEKTROMAT ST 60.24-50,00 and is the answer not in the manual?

Questions and answers

Summary of Contents for GFA ELEKTROMAT ST 60.24-50,00

  • Page 1 Installation Instructions ELEKTROMAT ST 60.24-50,00 Model: 10003259 00001 -en- Status: 08.04.2024...
  • Page 2 GfA ELEKTROMATEN GmbH & Co. KG Wiesenstraße 81 D-40549 Düsseldorf www.gfa-elektromaten.de info@gfa-elektromaten.de...
  • Page 3: Table Of Contents

    Table of contents General safety information .................... 4 Technical data ......................6 Mechanical installation ....................7 Electrical installation ....................11 Motor connection ......................11 Limit switch connection ....................12 Completing commissioning / inspection ............... 13 Disposal ........................15 Declaration of incorporation / Declaration of conformity ..........16 10 UKCA: Declaration of incorporation / Declaration of conformity ........
  • Page 4: General Safety Information

    Observe all specifications, especially warnings, when installing the product in the overall system. GfA is not liable for damage resulting from non-observance of the installation instructions. The resulting overall system must be reassessed for its safety in accordance with applicable standards and directives (e.g. CE marking).
  • Page 5 Warning - Failure to follow these installation instructions may result in severe injury or death. • Please read these instructions before using the product. • Keep these instructions handy. • Include these instructions when passing on the product to third parties. Warning - Danger from improper use of the product! •...
  • Page 6: Technical Data

    2 Technical data Designation Unit Output speed Output torque 600 (480) Output / hollow shaft 50,00 Series SG 115R Limit switch range (maximum revolutions of the output / hollow shaft) Supply voltage 3N~ 400 Operating current 3,90 Operating frequency Power factor cos φ 0,76 Safety circuit Degree of protection...
  • Page 7: Mechanical Installation

    3 Mechanical installation Requirements The permissible loads on walls, mountings, connection and transmission elements must not be exceeded even for maximum holding or locking torque (▶ observe technical data). Connection elements Use self-locking connection Use a screw that precisely Use adequately elements with a minimum fits the hole.
  • Page 8 Mounting 4 boreholes are provided for mounting.
  • Page 9 Installation The following descriptions refer to a door which is not further defined. The door manufacturer's specifications must also be observed. Warning – Injury or danger to life possible! • Use a lifting device with sufficient load-carrying capacity for installation tasks. •...
  • Page 10 Tighten all connection elements (M16) with a BAGAE004302_Z003 torque of 175 Nm. Install all further connection elements according to the 175 Nm specifications of the door manufacturer. Warning – Injury or danger to life possible! • Disconnect the electrical voltage for the setting of the slipping clutch. The slipping clutch acts as an overload BAGAE4303_Z003 protection.
  • Page 11: Electrical Installation

    4 Electrical installation Warning - Danger to life from electric current! • Switch the mains OFF and check that the cables are de-energised • Observe the applicable regulations and standards • Make the electrical connection according to standard • Use suitable tools •...
  • Page 12: Limit Switch Connection

    Half-wave rectifier BAMA120012_Z001 Motor Magnetic brake U1 V1 W1 6 Limit switch connection Thermal contact BANA007002_Z001...
  • Page 13: Completing Commissioning / Inspection

    7 Completing commissioning / inspection Check the following components and then install all covers. Gearbox Check the drive unit for loss of oil (a few drops can be neglected). Protect the output-shaft permanently against corrosion. Mounting Check that all connection elements (consoles, torque mounts, screws, locking rings, etc.) are secure and in proper condition.
  • Page 14 Brake Warning - Potential injury or danger to life! • Carry out a brake test. Overrun depends on the door and its equipment. The specifications of the door manufacturer must be observed. In an environment that can affect the coefficient of friction of the brake pad (atmosphere with oil, solvents, detergents, etc.), class of protection IP65i must be adopted.
  • Page 15: Disposal

    Dispose of old devices properly according to local legal regulations. Return old devices to the return and collection systems available. You can also return GfA products free of charge. Please apply enough postage to the package and mark it as "old devices".
  • Page 16: Declaration Of Incorporation / Declaration Of Conformity

    EMC Directive 2014/30/EU within the meaning of RoHS Directive 2011/65/EU The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Machinery Directive 2006/42/EC are met: declare under our sole responsibility that the 1.1.2, 1.1.3, 1.1.5, 1.2.2, 1.2.3, 1.2.6, 1.3.2,...
  • Page 17: Ukca: Declaration Of Incorporation / Declaration Of Conformity

    Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 The following requirements from Appendix I of GfA ELEKTROMATEN GmbH & Co. KG the Supply Machinery (Safety) Regulations 2008 declare under our sole responsibility that the...