USER'S INFORMATION,
MAINTENANCE AND
SERVICE MANUAL
HIGH EFFICIENCY
TUBULAR HEAT EXCHANGER SERIES
MODELS: GY8S*DH, GM8S*DH / LY8S*DH / LM8S*DH
(Single Stage Downflow/Horizontal / LoNOx)
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
USER'S INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 3
START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . 3
to Start the Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operating Instructions: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
To Turn Off the Appliance: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . 3
Air Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Removing Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Blower Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Motor Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . 4
SAFETY SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

CONTACT INFORMATION

• Go to website at www.york.com click on "contact", then click on "contact form" and follow the instructions.
• Contact us by mail:
The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.
FIRE OR EXPLOSION HAZARD - Failure to follow safety
warnings exactly could result in serious injury, death, or prop-
erty damage.
-
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
-
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
(including cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire depart-
ment.
-
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.

TABLE OF CONTENTS

FURNACE MAINTENANCE SECTION . . . . . . . . . . . . . . . . . . . . . . .4
FURNACE CLEANING SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Burner Removal/Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Cleaning the Heat Exchanger . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Continuous Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Intermittent Blower - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Heating Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Hot Surface Ignition System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
FURNACE CONTROL DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . .6
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . .10
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
EXCLUSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
York International
Consumer Relations
5005 York Drive
Norman, OK 73069

SECTION I: USER'S INFORMATION

SAFETY

1.
The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.
2.
Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.
3.
The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.
4.
Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 3 of this manual when lighting the furnace or turning the
furnace off.
5.
Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.
6.
Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
127936-UUM-A-0505

Advertisement

loading
Need help?

Need help?

Do you have a question about the GY8S DH Series and is the answer not in the manual?

Questions and answers

Summary of Contents for York GY8S DH Series

  • Page 1: Table Of Contents

    EXCLUSIONS .........12 CONTACT INFORMATION • Go to website at www.york.com click on “contact”, then click on “contact form” and follow the instructions. • Contact us by mail:...
  • Page 2: Fire Or Explosion Hazard

    127936-UUM-A-0505 INSTRUCTIONS FOR EXAMINING THE FURNACE VENT PIPE INSTALLATION FLUE COLLAR It is the owner’s responsibility to ensure that an annual inspection of the ELECTRICAL entire heating portion of the unit is made by a qualified service agency. JUNCTION BOX CONTROL Examine the furnace as outlined below in steps “1 - 6”...
  • Page 3: How Your Gas Furnace Works

    127936-UUM-A-0505 HOW YOUR GAS FURNACE WORKS Turn off all electric power to the appliance if service is to be per- formed. Your furnace is a very easy appliance to take for granted. Season after Remove burner access panel. season, it sits there in your home, keeping you warm and comfortable. Move gas control switch to the “OFF”...
  • Page 4: Air Filters

    127936-UUM-A-0505 If, during the inspection of your furnace, you find any of the following conditions: • Excessive amounts of dust and lint on components. Make sure you DO NOT move the clip on weight on the • Damaged or deteriorated components or surfaces. indoor fan wheel when cleaning the wheel.
  • Page 5: Furnace Cleaning Section

    127936-UUM-A-0505 The furnace vent and combustion air intake passageways. Should Remove six mounting screws that hold the vent motor to the it be necessary to service the vent/air intake system, the manufac- restrictor plate. The surface is gasketed and the gasket can be turer recommends this service be conducted by a qualified service reused if it is carefully removed.
  • Page 6: Hot Surface Ignition System

    127936-UUM-A-0505 Review the sequence of operation. Start the system by setting the RED - LOW SPEED thermostat above the room temperature. Observe the system’s YELLOW - MED. LOW SPEED response. Then use the troubleshooting section in this manual to BLACK - HIGH SPEED check the system’s operation.
  • Page 7: Diagnostic Fault Code Storage And Retrieval

    127936-UUM-A-0505 7 RED FLASHES: This fault code indicates that the flame could not be IGNITION CONTROL (P/N 031-01973-000) established. This no-light condition occurred 3 times (2 retries) during Normal flame sense current is approximately the call for heat before locking out. Low gas pressure, faulty gas valve, 3.7 microamps DC (µa) faulty hot surface ignitor or burner problem may cause this.
  • Page 8: Section Iii: Replacement Parts List

    127936-UUM-A-0505 SECTION III: REPLACEMENT PARTS LIST 6,20 24,36 12,35 Unitary Products Group...
  • Page 9 127936-UUM-A-0505 ITEM DESCRIPTION ITEM DESCRIPTION PANEL, BURNER ACCESS MOTOR PANEL, BASE MOTOR,DIRECT DRIVE BLOWER BRACKET, DOOR MOTOR,VENTOR ASS’Y PANEL, BLOWER ACCESS ELECTRICAL PANEL, TOP CAPACITOR (7.5MFD/370V) WRAPPER, INSULATED CONTROL, HIGH LIMIT MISCELLANEOUS CONTROL,FURNACE FILTER (2 Req’d) (.75 x 14 x 20) IGNITOR FILTER BRACKET SENSOR, FLAME...
  • Page 10: Field Installed Accessories - Non-Electrical

    Click on the “Brand Links” button b. Click on the “Customer Service” button • You can contact us by mail. Just send a written request to: York International Consumer Relations 5005 York Drive Norman, OK 73069 Unitary Products Group...
  • Page 11: Section Iv: Wiring Diagram

    127936-UUM-A-0505 SECTION IV: WIRING DIAGRAM FIGURE 8: Wiring Diagram Unitary Products Group...
  • Page 12: Limited Warranty

    For Owner's Information: PRODUCT MODEL. NO. ____________________ INSTALLATION DATE ______________________________ UNIT SERIAL NO. _________________________ INSTALLING DEALER ______________________________ Subject to change without notice. Printed in U.S.A. 127936-UUM-A-0505 Copyright © by York International Corp. 2005. All rights reserved. Supersedes: Nothing Unitary 5005 Norman...

This manual is also suitable for: