USER'S INFORMATION,

MAINTENANCE AND
SERVICE MANUAL
HIGH EFFICIENCY
TUBULAR HEAT EXCHANGER SERIES
MODELS: P*XU/ G9D-UP
Two Stage (Upflow)
CONTACT INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
USER'S INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . 3
START-UP AND SHUTDOWN INSTRUCTIONS . . . . . . . . . . . . . . . 3
FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . . 5
SAFETY SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
FURNACE MAINTENANCE SECTION . . . . . . . . . . . . . . . . . . . . . . . 5
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

CONTACT INFORMATION

• Go to website at www.york.com click on "contact", then click on "contact form" and follow the instructions.
• Contact us by mail:
The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.
FIRE OR EXPLOSION HAZARD - Failure to follow safety
warnings exactly could result in serious injury, death, or prop-
erty damage.
-
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
-
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
(including cell phone) in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire depart-
ment.
-
Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.

TABLE OF CONTENTS

DIRECT DRIVE BLOWER MOTOR . . . . . . . . . . . . . . . . . . . . . . . . .6
INSTALLATION OF PSC MOTOR: . . . . . . . . . . . . . . . . . . . . . . . . . .6
FURNACE CLEANING SECTION . . . . . . . . . . . . . . . . . . . . . . . . . . .7
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
FURNACE DIAGNOSTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
REPLACEMENT PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . . .12
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
York International
Consumer Relations
5005 York Drive
Norman, OK 73069
SECTION I: USER'S INFORMATION

SAFETY

1.
The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.
2.
Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.
3.
The furnace needs air for combustion in order to operate properly
and safely. Do not block or obstruct air openings on the furnace,
air openings to the area where the furnace is installed, or spaces
around the furnace.
4.
Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 3 of this manual when lighting the furnace or turning the
furnace off.
5.
Should the gas supply fail to shut off or if overheating occurs, shut
off the gas valve to the furnace before shutting off the electrical
supply.
6.
Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all gas
controls, control system parts, electrical parts that have been wet
or the furnace if deemed necessary.
EFFICIENCY
RATING
CERTIFIED
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
035-19650-001 Rev. C (0404)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P XU Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for York P XU Series

  • Page 1: Table Of Contents

    CLICK ANYWHERE on THIS PAGE to RETURN to YORK HVAC AGE & MANUALS & ERROR CODES at InspectApedia.com USER’S INFORMATION, MAINTENANCE AND EFFICIENCY RATING CERTIFIED SERVICE MANUAL HIGH EFFICIENCY TUBULAR HEAT EXCHANGER SERIES This product was manufactured in a plant whose quality system...
  • Page 2: Instructions For Examining The Furnace Installation

    035-19650-001 Rev. C (0404) INSTRUCTIONS FOR EXAMINING THE FURNACE COMBUSTION INSTALLATION GAS VALVE AIR COLLAR BURNER It is the owner’s responsibility to ensure that an annual inspection of the entire heating portion of the unit is made by a qualified service agency. VENT PIPE Examine the heat exchanger, vent/combustion air piping, vent CONDENSATE...
  • Page 3: How Your Gas Furnace Works

    035-19650-001 Rev. C (0404) HOW YOUR GAS FURNACE WORKS To Turn Off the Appliance: Set the thermostat to lowest setting. Your furnace is a very easy appliance to take for granted. Season after season, it sits there in your home, keeping you warm and comfortable. Turn off all electric power to the appliance if service is to be per- For this reason, you may never have given much thought to the way formed.
  • Page 4 035-19650-001 Rev. C (0404) • Check for dirt or lint on any surfaces or on components. Do not try Reverse the procedure to reinstall filters. to clean any of the surfaces or components. Cleaning of the fur- nace and its components must be done by a qualified service pro- POSITION WIRE RETAINER (IF PROVIDED) UNDER FLANGE fessional.
  • Page 5: Service And Maintenance Manual

    035-19650-001 Rev. C (0404) SEQUENCE OF OPERATION Motor Lubrication The motors in these furnaces are permanently lubricated, and do not The following describes the sequence of operation of the furnace. Refer require periodic oiling. to Figure 1 for component location. Every time the filters are changed the following items should be visually Call for 1st stage only inspected:...
  • Page 6: Direct Drive Blower Motor

    035-19650-001 Rev. C (0404) 1st and 2nd Stage satisfied simultaneously The air cleaner and the blower motor are energized through the ignition control or directly through the motor. • Both stages of the Gas Valve are de-energized. • Flame Rectification is lost. DIRECT DRIVE BLOWER MOTOR •...
  • Page 7: Furnace Cleaning Section

    035-19650-001 Rev. C (0404) TABLE 2: Replacement PSC Motor / Capacitor Information High Fire Inputs Airflow Motor Motor Capacitor Capacitor Cabinet Size Part Number Horsepower Part Number Rating BTU/H (kW) CFM (m³) 60,000 (17.6) 1,200 (33.98) 024-23271-000 024-20045-000 7.5 f 80,000 (23.4) 1,600 (45.31) 024-26002-000...
  • Page 8: Furnace Diagnostics

    035-19650-001 Rev. C (0404) FURNACE DIAGNOSTICS Effect: Control enters ‘Soft Lockout’. It will automatically reset and try again after 1 hour. Control Module Fault Code Explanatios Causes: Restricted vent system 1 Flash (Continuous Flash; 1 second on, 1 second off) Vent system that exceeds specifications Reason: Flame sensed without a call for heat.
  • Page 9 035-19650-001 Rev. C (0404) W2 SIGNAL HIGH INDUCER HIGH STAGE PRESSURE SWITCH AND 2ND STAGE MAIN VALVE CIRCULATOR HIGH HIGH HEAT SPEED HEAT DELAY 30 SEC. CALL HIGH HEAT AFTER LOW HEAT IS ESTABLISHED 2ND STAGE CLOSED HIGH LIMIT OPEN W1 SIGNAL INDUCER CLOSED...
  • Page 10: Replacement Parts List

    035-19650-001 Rev. C (0404) SECTION III: REPLACEMENT PARTS LIST 41,43 Unitary Products Group...
  • Page 11 035-19650-001 Rev. C (0404) ITEM DESCRIPTION ITEM DESCRIPTION PANEL, FRONT (Blower) MOTOR PANEL, FRONT (Burner) MOTOR, DIRECT DRIVE BLOWER PANEL, FRONT (Burner) MOTOR,VENTOR ASS’Y PANEL, TOP MOTOR,VENTOR ASS’Y SUPPORT, BURNER ELECTRICAL WRAPPER, CABINET (Insulated) CAPACITOR (7.5MFD/370V) WRAPPER, CABINET (Insulated) CAPACITOR (10 MFD/370V) PANEL, VESTIBULE (Lower) CAPACITOR, VENTOR (4MFD/370V)
  • Page 12: Field Installed Accessories - Non-Electrical

    Click on the “Brand Links” button b. Click on the “Customer Service” button • You can contact us by mail. Just send a written request to: York International Consumer Relations 5005 York Drive Norman, OK 73069 Unitary Products Group...
  • Page 13: Wiring Diagram

    035-19650-001 Rev. C (0404) SECTION IV: WIRING DIAGRAM FIGURE 9: Wiring Diagram Unitary Products Group...
  • Page 14 035-19650-001 Rev. C (0404) NOTES Unitary Products Group...
  • Page 15 035-19650-001 Rev. C (0404) Unitary Products Group...
  • Page 16: Limited Warranty

    PRODUCT MODEL. NO. ____________________ INSTALLATION DATE ______________________________ UNIT SERIAL NO. _________________________ INSTALLING DEALER ______________________________ Subject to change without notice. Printed in U.S.A. 035-19650-001 Rev. C (0404) Copyright © by York International Corp. 2004. All rights reserved. Supersedes: 035-19650-001 Rev. B (0204) Unitary 5005...

This manual is also suitable for:

G9d-up

Table of Contents