Flue gas values in accordance with DIN 4705, DIN 18895 part 2
When door is closed
Flue gas quantity
Flue gas temperature
Pre-pressure
Yield
CO at 13% O2
Particulate matter
Certificate Institute 1625. Test standard EN 13240. Test report no. RRF-400169
Target value for the volume of the space to be heated:
Not all spaces meet the present insulating values. According to DIN 18893, the following values can be taken for
the volume of the space to be heated:
If heating circumstances are favourable:
In less favourable circumstances:
In unfavourable circumstances:
For temporary heating you may assume a reduction of 25% for the volume to be heated if the interval is more
than 8 hours.
Table for thickness of insulation cf thickness of the wall
Protection of the wall
Walls made of combustable construction parts
Supporting walls in steel construction
Intergrated pieces against stove
Intergrated pieces in the wall behind
Other walls
Wall thickness < 10 cm
Wall thickness > 10 cm (e.g. a brickwork wall)
Table gives the insulation thickness to be used for a given wall thickness to protect intergrated wall.
logs
8.4
g/s
290
˚C
0.12
mbar
78.9
%
0.07
%
26
mg/m3
Calculate according to DIN 4701
135 m3
95 m3
Wall thickness
10 cm
X
X
X
X
X
-
Insulation
Convection
house
back side
8 cm
on the side
8 cm
under side
6 cm
X
X
X
X
X
-