Cisco 7606-S Installation Manual page 58

Field-replaceable units (frus)
Hide thumbs Also See for 7606-S:
Table of Contents

Advertisement

Removing and Replacing the Power Supply
For proper 2700 W DC-input redundant power configuration, all two pairs of input wires for one 2700W
Note
DC-input power supply must come from the same battery system (A feed); all two pairs of input wires
for the other 2700 W DC-input power supply must come from another battery system (B feed).
Note
For multiple DC input power supply, each DC input must be protected by dedicated circuit breaker or
fuse. The circuit breaker or fuse should be sized according to the power supply input rating and local or
national electrical code requirements.
Figure 5-62 DC-Input Front Panel for 2700-W DC-Input Power Supply
4
1
Captive installation screw
2
DC power cable terminal block
3
Status LEDs
4
DC power cable terminal block cover
5
Cable holder cover
6
Ground
Warning
Power supply captive installation screws must be tight to ensure protective grounding continuity.
Remove the four screws securing the terminal block cover, and slide the cover off of the terminal block
Step 5
(Figure
Attach the appropriate lugs to the DC-input wires. The maximum width of a lug is 0.600 inch (15.2 mm).
Step 6
The wire should be sized according to local and national installation requirements. Use only copper wire.
Cisco 7600 Series Router Installation Guide
5-58
1
6
5
5-62).
Chapter 5
2
3
P W R -2
7 0 0 -D C
/6
IN P U T1
-V E -1
IN P U T2
O K
FA N
O U TP U
48 V- 60
O K
V
O K
48 V- 60
FA IL
=4 0A
V
=4 0A
-V E -1
-V E -2
-V E -2
A LL FA
S TE N E
P R IO R
R S M U
TO O P
S T B E
E R A TI
FU LL Y
N G TH
E N G A
E P O W
G E D
E R S U
P P LY
8
9
7
10
7
Cable holder cover
8
Cable holder
9
Tie-wrap
10 Cable holder
11 Tie-wrap
Removal and Replacement Procedures
T
11
OL-4503-24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7600 series

Table of Contents