Device overview
Components
Lists and identifies the physical parts of the scale with numerical labels.
Operating elements
Describes the scale's buttons, numerical input methods, and display indicators.
Basic information (general)
Intended use
Defines the primary function and operation mode of the weighing scales.
Improper use
Lists prohibited uses that can lead to damage or incorrect results.
Guarantee
Outlines the conditions under which the product warranty expires.
Test equipment monitoring
Explains the importance and process of monitoring metrological properties.
Basic safety instructions
Observe the notes in the operating instructions
Emphasizes reading all instructions before installation and commissioning.
Staff training
States that only trained personnel should operate and maintain the appliance.
Transport and storage
Control on takeover
Instructs users to check packaging and appliance for damage upon receipt.
Packaging/return transport
Provides guidelines for keeping original packaging and preparing for transport.
Unpacking, installation and commissioning
Installation site, place of use
Provides guidelines for selecting an optimal installation location for accurate results.
Unpacking and checking
Details the process of removing items from packaging and verifying contents.
Assembly, installation and levelling
Explains how to assemble components and level the scale for accurate weighing.
Mains connection
Guides on connecting the scale to the power supply and important electrical checks.
Connection of peripheral devices
Explains how to connect external devices like printers and PCs.
Initial commissioning
Covers the final steps for starting up the scale and achieving accurate readings.
Adjustment
External adjustment
Details the step-by-step process for performing external calibration using adjustment weights.
External adjustment with user-defined adjustment weight
Explains how to perform external calibration using a weight value defined by the user.
Internal adjustment
Describes the process for performing internal calibration of the scale.
Automatic internal calibration (isoCAL)
Explains the function and activation of automatic internal calibration.
Basic operation
General instructions for operating with draft shield
Advises on closing scale doors for accurate results when using a draft shield.
Switch on
Guides on the procedure for powering on the scale and its self-test sequence.
Standby mode
Explains how to put the scale into standby mode and its implications.
Zeros
Details the process of zeroing the scale before weighing for optimal accuracy.
Taring
Explains how to tare the scale to measure net weight of goods.
Applications
Selection of a weighing application
Describes how to navigate the menu to select different weighing applications.
Simple weighing
Details the parameters and steps for performing a basic weighing operation.
Carry out underfloor weighing
Provides instructions and safety notes for underfloor weighing.
Changing the weighing unit
Explains how to activate and select different weighing units.
Counting
Explains the counting application, determining average piece weight for counting.
Percentage weighing
Describes how to determine the percentage of a sample relative to a reference weight.
Net total
Explains the Net Total function for weighing individual components of a mixture.
Dynamic weighing
Details the dynamic weighing application for unsteady loads like animals.
Calculation
Explains how to perform calculations using multiplication or division.
Density determination
Outlines the steps and parameters for determining the density of solids.
Statistics function
Describes how the statistics function records and analyzes measured values.
Peak value function
Explains how to determine the maximum weight value (peak value) of a sample.
Tolerance weighing
Details how to set tolerance ranges to check if values are within limits.
Totalise
Explains the Totalise function for summing up weights of multiple samples.
Menu
Navigation in the menu
Explains how to navigate through the scale's menu system using buttons.
Main menu
Provides an overview of the main menu structure and its levels.
Setup menu
Basic scale settings
Details the configuration options for ambient conditions, app filter, and stability settings.
Factory settings
Explains how to restore factory settings or prevent their modification.
Device settings
User customisations
Describes how to customize menu access and audible signals.
Interface settings
Details settings for baud rate and other parameters for RS232, RS485, and USB interfaces.
Communication with peripheral devices
RS232 / RS485 interface
Describes the RS232/RS485 interface, connection, and pin assignment.
USB-C connection
Specifies the USB-C connection type and compatible devices.
Connecting the printer to a scale
Guides on how to connect a printer to the scale and ensure compatibility.
Maintenance, servicing, disposal
Cleaning
Provides instructions on how to clean the scale safely and effectively.
Maintenance, servicing
States that only authorized technicians should perform maintenance or servicing.
Waste disposal
Advises on disposing of the appliance and packaging according to regulations.