General Notes
Intended use
Describes the intended application and safe operation of the IR camera.
Warranty
Details the warranty period, conditions, and exclusions for the product.
Scope of delivery
Lists all components included in the standard delivery package of the camera.
Maintenance
Provides instructions for cleaning and general upkeep of the IR camera to ensure performance.
Technical Data
General specifications
Outlines environmental, physical, and general operating specifications of the Xi cameras.
Electrical specifications
Details power supply requirements, current draw, and electrical interface characteristics.
Measurement specifications
Covers temperature ranges, spectral response, detector types, and lens options for each model.
Optical specifications
Explains focus adjustment, lens choices, and geometric resolution parameters for optimal measurement.
Mechanical Installation
Dimensions
Provides detailed dimensional drawings and mounting thread information for Xi cameras.
Accessories
Describes various optional accessories available for enhancing camera functionality and protection.
Air purge laminar
Explains the air purge system for keeping the lens clean and preventing errors.
Water cooling
Details the water cooling system for high ambient temperature applications and its mounting.
Shutter
Describes the optional shutter mechanism for protecting the camera optics from dirt.
Combination of air purge, water cooling and shutter
Explains how to combine air purge, water cooling, and shutter accessories for integrated functionality.
Outdoor protective housing
Covers the outdoor protective housing for using the camera in outdoor environments.
Electrical Installation
Process interface
Explains how to connect and configure the camera's process interface for analog and digital signals.
Process interface Xi 80/410/410 MT/1M
Details the analog and digital input/output configurations for specific Xi models.
Process interface Xi 400/640
Describes the process interface configuration for Xi 400/640 models, including analog and digital I/O.
PIN allocation Xi 80/410/410 MT/1M
Shows the pin assignments for USB, Ethernet, and PIF connectors on specific Xi models.
PIN allocation Xi 400/640
Details the pin assignments for USB and PIF connectors on Xi 400/640 models.
Industrial Process Interface for Xi 80/410/410 MT/1M (optional)
Explains the optional industrial process interface for demanding environments and its pinout.
Industrial Process Interface for Xi 400/640 (optional)
Covers the optional industrial process interface for Xi 400/640 models and its pin assignments.
Example for a Fail-Safe monitoring of the Xi with a PLC
Illustrates how to implement fail-safe monitoring of the camera using a PLC system.
USB cable extension for Xi 400/640
Discusses extending the USB connection range for Xi 400/640 cameras using a USB server.
Functions
Ethernet Xi 80/410/410 MT/1M
Describes Ethernet connectivity for Xi models, including setup and power options.
Ethernet setup (Point-to-Point-Connection)
Guides through configuring PC network settings for a direct Ethernet connection to the camera.
Autonomous operation Xi 80/410/410 MT/1M
Explains how to operate the camera autonomously without a permanent PC connection.
Hot- / Coldspot function in autonomous operation
Details setting up hot/cold spot analysis for autonomous camera operation.
Use of Shutter
Explains the operation and control of the optional shutter system for camera protection.
Software PIX Connect
Installation and initial start-up
Guides through the installation process and initial setup of the PIX Connect software.
Software window
Provides an overview of the PIX Connect software interface and its main components.
Basis features of the software PIX Connect
Highlights key features of the PIX Connect software, including customization and analysis capabilities.
Emissivity
Definition
Defines emissivity and its importance in accurate infrared temperature measurements.
Determination of unknown emissivity
Provides methods for determining unknown emissivity values for accurate measurements.
Characteristic emissivity
Discusses factors influencing emissivity and how to use emissivity tables.
Appendix C – Quick start for serial communication
Setup of the interface
Details the steps to configure the PIX Connect software for serial port communication.
RS485 for Xi 80/410/410 MT/1M
Explains the RS485 connection and requirements for specific Xi camera models.
Appendix F – Wiring diagrams PIF for Xi 400/640
Analog Output:
Describes the analog output functionality and configuration for the PIF.
Digital Input:
Explains the digital input functionality and activation methods for the PIF.