1. DESCRIPTION
Viking Quick Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are
thermosensitive spray sprinklers suitable for use in areas subject to freezing.
These dry pendent ELO sprinklers are FM Approved for storage and non-storage
applications. In certain FM cold storage installations, the dry ELO sprinklers
can provide a design advantage with lower overall water demands. In these
applications, the dry ELO must be installed on a wet pipe system, per FM data
sheet 8-9. In non-storage applications, when used in dry or preaction systems,
the sprinklers are designed to prevent water or condensation from entering the
drop nipple before the sprinkler operates. Viking Quick Response Dry Pendent
ELO Sprinklers are available in various finishes and temperature ratings to meet
design requirements.
The optional dry sprinkler boot assembly is intended to slow the exchange of air
between the inside and outside of the freezer (or any dry sprinkler installation)
to help prevent humidity and temperature differential in the area around the
sprinkler. Condensation can lead to ice build-up, which could inhibit sprinkler
operation or cause premature operation.
If using the insulating boot assemblies included with your sprinklers (optional
for installation), follow the installation instructions in this technical data page.
Insulating boot assemblies, if used, shall be installed on smooth, flat, and clean
surfaces. There are specific installation situations, as with corrugated ceiling
panels, where alternative penetration sealing methods may be utilized. For
additional information contact Viking Technical Services.
2. LISTINGS AND APPROVALS
FM Approved: Classes 2013 and 2015
Refer to Approval Chart and Design Criteria for FM Approval
requirements that must be followed.
3. TECHNICAL DATA
Specifications:
Minimum Operating Pressure: 7 psi (0.5 bar)*
Maximum Working Pressure: 175 psi (12 bar).
Factory tested hydrostatically to 500 psi (34.5 bar)
Thread size: 1-1/4" NPT or 32 mm BSPT
Nominal K-Factor: 11.2 U.S. (161.3 metric**) for all listed and approved lengths.
Covered by the following U.S. Patents: 10,220,231
* FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar).
**Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.
Material Standards:
Frame Casting: Brass UNS-C84400
Deflector: Brass
Fusible Link Assembly: Beryllium Nickel, coated with Polyurethane
Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape
Compression Screw: Brass UNS-C36000
Pip Cap: Brass UNS-C36000
Pip Cap Adapter: Brass UNS-C36000
Orifice: Brass UNS-C36000
Tube: ERW Hydraulic Steel Tube
Barrel End and Threads: QM Brass
Support (Internal): QM Brass
Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish
Form No. F_040915
21.09.28
TECHNICAL DATA
The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058
Rev. 21.1
QUICK RESPONSE
DRY PENDENT
ELO SPRINKLERS
Thread Size
1-1/4" NPT
(32 mm BSPT)
SIN
VK547
VK548
VK549
Replaces Form No. F_040915 Rev 20.1
(Revised Ceiling opening dimensions; Updated format.)
Page 1 of 9
K-Factor
11.2
(161.3 Metric)
Style
Plain Barrel
Adjustable Recessed
Adjustable Standard

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VK549 and is the answer not in the manual?

Questions and answers

Summary of Contents for Viking VK549

  • Page 1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 1. DESCRIPTION Viking Quick Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing.
  • Page 2: Technical Data

    Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Dry Barrel Seals: (NOTE: 2 seals included with each VK547 and 1 with each VK548 or VK549): Seal:...
  • Page 3 A. Adjustable Standard Dry Escutcheon: Base Part No. 19730. B. Recessed Dry Escutcheon Cup: Base Part No. 19728. Dry Barrel Seals: (NOTE: 2 seals are included with each VK547 and 1 with each VK548 or VK549) Part No. 22089M/W Footnotes Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix.
  • Page 4 F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable.
  • Page 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For “A” Dimension: 1. Determine the distance from the face of the tee to the finished ceiling.
  • Page 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For “A” Dimension: 1. Determine the distance from the face of the tee to the finished ceiling.
  • Page 7 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For “A” Dimension: 1. Determine the distance from the face of the tee to the base of the sprinkler.
  • Page 8 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Install 1-1/4” NPT (32 mm BSP) threaded end of dry pendent Exposed Barrel Ambient Temperature sprinkler into the 1-1/4”...
  • Page 9 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Barrel Seal assembly (optional) Part No. 22089M/W...
  • Page 10 Refer to the appropriate technical data page and NFPA standards for complete care, handling, installation, and maintenance instructions. For additional product and system information Viking data pages and installation instructions are available on the Viking Web site at www.vikinggroupinc.com.
  • Page 11 * Refer to the appropriate current technical data pages for complete care, handling, and installation instructions. Data pages are included with each shipment from Viking or Viking distributors. They can also be found on the Web site at www. vikinggroupinc.com.
  • Page 12 • while ceiling finish work is being completed. Use only the designated Viking recessed sprinkler wrench (refer to the appropriate sprinkler data page) to install these sprinklers. NOTE: The protective cap is • temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed.
  • Page 13 Take care not to crack the wax coating on the units. • For touching up the wax coating after installation, wax is available from Viking in bar form. Refer to Table 1 below. The coating MUST be repaired after •...
  • Page 14: Listings And Approvals

    1. DESCRIPTION Viking fire sprinklers consist of a threaded frame with a specific waterway or orifice size and a deflector for distributing water in a specified pattern. A closed or sealed sprinkler refers to a complete assembly, including the thermosensitive operating element. An open sprinkler does not use an operating element and is open at all times.
  • Page 15 TECHNICAL DATA SPRINKLER OVERVIEW The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com VERTICAL SIDEWALL (VSW) SPRINKLER: A sprinkler intended for installation near the wall and ceiling. The deflector provides a water spray pattern outward in a quarter-spherical pattern and can be installed in the upright or pendent position with the flow arrow in the direction of discharge.
  • Page 16 Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking’s current list price schedule or contact Viking directly.
  • Page 17 STANDARD RESPONSE, QUICK RESPONSE, EXTENDED COVERAGE, AND DRY SPRINKLERS Viking thermosensitive spray sprinklers consist of a small frame and either a glass bulb or a fusible operating element. Available styles include pendent, flush pendent, concealed pendent, upright, horizontal sidewall, vertical sidewall, or conventional, depending on the particular sprinkler model selected.
  • Page 18 C. Installation Instructions - Dry Sprinklers WARNING: Viking dry sprinklers are to be installed in the 1” outlet (for dry and preaction systems), or run of malleable, ductile iron, or Nibco CPVC* threaded tee fittings (for wet systems) that meet the dimensional requirements of ANSI B16.3 (Class 150), or cast iron threaded tee fittings that meet the dimensional requirements of ANSI B16.4 (Class 125), even at branch line ends.
  • Page 19 4. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the installation stand- ards. Viking high pressure sprinklers may be hydrostatically tested at a maximum of 300 psi (20.7 bar) for limited periods of time (two hours), for the purpose of acceptance by the Authority Having Jurisdiction.
  • Page 20 Refer to the Authority Having Jurisdiction for minimum replacement requirements. 7. AVAILABILITY Viking sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation.
  • Page 21: Warranty Terms And Conditions

    For more information, go to www.P65Warnings.ca.gov 2. WARRANTY TERMS AND CONDITIONS For details of warranty, refer to Viking’s current list price schedule at www.vikinggroupinc.com or contact Viking directly. New Bulletin Form No. F_111218 18.11.15...

Table of Contents