Page 2
The manual updates are not to be further notified. Applicable Models This manual provides the installation, operation and maintenance of PV TP4KTL-TP25KTL grid-connected inverters . The following models of inverter are related: ·...
Symbols on the inverter Important safety instruction The inverter is attached with some labels related to operation safety. Please Symbols in this manual don't install the device until carefully read through and fully understand these To ensure the personal and property safety in using the photovoltaic inverter and labels.
5.4.4 Protection mode..................30 Tip Please contact us if you have any problems. 5.4.5 Fault state....................30 TP4KTL-TP25KTL 5.5 LCD panel power saving mode................31 Series inverters are designed, manufactured and tested as per international safety standards. However as an electrical and electric 5.6 LED blink table....................
1.2 During installation Do NOT restart the inverter before all the hazards have been removed. Please contact your local dealer and Notice always have licensed trader do the repairing. Keep the PV array covered and the DC circuit breaker Danger OFF.
2 Product description 2.1 Product applicability By TP series inverter, the DC voltage generated in the PV array can be trans- formed into AC voltage and supplied to the grid. The PV power generating system consists of PV arrays, inverters, meters and a public grid. 2.3 Product introduction 2.3.1 Electrical connecting part PV Array...
Page 8
Tab.2-2:Inverter weight Tab. 2-1: Description for the electrical connecting part of the inverter Name Description The positive part of terminals connecting Model TP4KTL Weight 16 Kg the PV array Model TP5KTL Weight 16 Kg The negative part of terminals connecting...
3 Installation 3.3 Preparation before installation 3.3.1 Unpacking and checking 3.1 Safety instruction The product is carefully tested and checked before transportation, however it is The DC voltage at the PV array and the AC voltage at still possible to be damaged during transportation, please check the device the grid side are both higher than the safe voltage.
Page 10
3.3.2 Preparation for tools The inverter shall be installed in a cool & dry place with temperature from -25℃-+60℃; The environmental relative humidity is not higher than 95% The following tools will be used for installing the inverter: and without any condensation. The inverter LCD shall be leveled with eyes and with enough space in the front for inspection.
Step3: Lift and hang the inverter on the wall,lock the nuts, and fix the machine 3.5 Inverter installation Please check that the open circuit voltage, short circuit current and maximum power at STC of the PV array are Danger within the capacity of the solar inverter. The full load MPPT voltage range is within the 250V-850V.
Page 12
3.6.1 Electric and electrical system structure Tab.3-3: suggested max power input -Each string of solar panels in series should be of same type and specification. The electric and electrical connection for the whole solar energy power -Open Circuit Voltage of each string should not exceed 1000VDC generation system is shown as below: -The two string of same MPP tracker should have same number of solar panels.
Page 13
3) Communication terminals The wring terminals as following: 4) Cables of the following specification will be equipped by the user. Tab.3-4: Recommended cable specification Recommended 2) AC terminals Min. sectional Max. sectional area sectional area ( m㎡) area ( m㎡) (m㎡)...
3.6.3.1 Steps for DC connection When designing the PV array, make sure the maximum open Caution Steps for DC cable wiring circuit voltage is not higher than 550V at each series of PV group. Otherwise the inverter will be damaged irreversibly 1) Using the striping tool to cut the PV cable, and makes the cooper wire reveal as 0.7cm.
4) Crimp closely between the terminal and PV cable. 3.6.3.2 Steps for AC connection TP4KTL-TP15KTL Fig.3-22 5) The terminal is crimped well with PV cable wire. Crimp the terminals with crimping Set the parts on the cable,Insert pliers the terminal holes in sequence Fig.3-23...
Male and female butt(plate end) he main body is inser ted into the core Tighten the nut with an open-end and a “click”is heard. wernch with a “click,click” sound The installation arrow indicates complete the installation insertion the female connector TP17KTL-TP25KTL Insertthe female terminal of the wire Completion of the installation...
4 Trial operation 4.1 Check before operation Necessary safety check must be performed before the Warning inverter is electrified for trial operation! 4.1.1 Check for reliability of mechanical installation Hold the release button inone hand Use a screw driver to peel off the red Check if the inverter is firmly installed and if all bolts are reliably tightened.
5.2 Internal data storage 5 Human-machine interaction 5.1 LCD interface The device has internal data storage function when use wifi communication, every a certain time, data will be autosaved, when occurring network fauIt, data can't be uploaded to the server, when network gets weII, the stored data will be uploaded to the server again.
5.4 Inverter working mode After the inverter is started up, the normal working state will be switched as per 5.4.2 Ready mode the chart below: When the DC voltage is over 100V, the inverter enter into the ready mode. In this case, inverter start hardware self-checking,and after the self-checking is DC<250v Power off...
5.4.4 Protection mode If any external fault such as AC side grid fault is detected by the inverter, the In the morning and evening, the light intensity is weak and inverter will stop power generating and enter the protection mode, in this case changeful, thus the LCD keep flashing.
6 Troubleshooting and maintenance Tab. 6-1: Protection code and solution 6.1 Troubleshooting This part introduces the common fault and solving steps, provides troubleshoot- Displayed code Protection description Recommended solution ing method and skills to the user, and helps the user identify and solve some common fault of the inverter.
Displayed code Fault description Recommended solution Displayed code Protection description Recommended solution Check whether all the three phase lines 1.Switch off the DC breaker. P011 Phase loss are connected to the grid. 2.Check if the system is designed incorrectly(DC1 power too high). E004 The DC1 input The inwerter will recover cutomatically...
7 Uninstallation 7.2 Packing The inverter shall be treated as per the following steps if it is to be replaced or out of service. Please pack the inverter with the original package if possible. If the original package is not available, please pack with a carton satisfying the following 7.1Uninstalling steps requirement.
8 Technical parameters Tab.8-2: Technical P arameter Model No Model No TP4KTL TP5KTL TP6KTL TP8KTL TP10KTL TP12KTL TP15KTL TP4KTL TP5KTL TP6KTL TP8KTL TP10KTL TP12KTL TP15KTL Input ( DC) General Parameters Max DC power (W) 5500W 6500W 7500W 9500W 11500W 18000W...
Page 25
Tab.8-2: Technical P arameter Model No Model No TP17KTL TP20KTL TP25KTL TP17KTL TP20KTL TP25KTL Input ( DC) General Parameters Max DC power (W) 25500W 30000W 30000W Dimension (W/H/D)(mm) 520*510*160 Max DC voltage (Vdc) 1000Vd.c. Weight (kg) Min working voltage (Vdc) 250Vd.c.
9 Quality assurance 9.3 Warranty card Tab. 9-1: Warranty card 9.1 Warranty Policy For our customers we provide 5 years standard warranty from the date of installation, you can also upgrade your standard warranty to 10 years. Please keep the purchasing invoice and trade mark clear for warranty. For more infor- mation, please contact your local dealer.