Introduction Introduction SAFETY WARNING 1.1.2 1 Introduction The inverter must be installed according to the local standard and Safety Symbols &Warnings ? 心 related standard for an electrical ente「prise. Please follow the EPH series hybrid inverters are designed , manufactured and tested as per international instructions in this manual to use and operate the inverter.
Inst「uction Instruction 1.3.2 Battery backup mode 1.2 System Diagram In this mode, it is necessary to ensure that the battery is charged regardless of whether ---- - 竺 日 尸 一 there is photovoltaic or not. ---- ---· Smart Meter 回一...
Introduction Installation 2 Installation 1.3.4.1) In the valley level, the grid and PV charge the batteries.(Fig:1.3.4.1) 2.1 Unpacking and Checking On receiving the inverter, please check before installation to make sure all the components as below are not missing or damaged. SYSTEM GRID METER...
Installation Installation 2.3 Mounting Leave enough space around the inverter as shown below: 2.3.1 Requirements For Mounting The installation of the inverter should be protected under shelter from direct sunshine or 40CM any bad weather conditions as shown below: Position Min.Size(CM) Front 40CM...
Installation Installation 2.4.2 Overview Of The Electrical Connecting Part Step3: Lift and hang the inverter on the wall,lock the nuts, and fix the machine. Meter Battery WIFI Back-up On-Grid DRED Power Fig.2.8 2.4.3 PV Connection Before connecting PV panels/strings to inverter, please make sure: Fig.2.6 1) Use the right PV connectors in the accessory box.
Page 8
Installation Installation 2.5 Battery Connection Battery connection diagram STEP1: Assemble the battery connectors from the accessory box.(battery cable must be firmly crimped into connectors) Meter Battery WIFI Back-up On-Grid DRED Power Fig.2.12 STEP2: Connect the battery connectors to the inverter. There will be a click sound if connectors are inserted correctly into battery plugs.
Installation Installation 2.6 Grid & EPS Connection Use the AC connectors from accessory box for grid and EPS connection. An external AC ※Inductive load: a non-frequency conversion air conditioner within 1.5P can be connected breaker(32A) is needed for on-grid connection to isolate from grid to EPS side.
Operating of the Inverter Operating of the Inverter 3 Operating of the Inverter The LCD display shows the detailed information of the inverter 3.1 LED and LCD Display The LED indicators are shown as blow: PV12 Status Explanation System is powered up SYSTEM System is not powered up Grid is normal...
Ope「ating of the l nverte「 Operating of the Inverter 3.2 Monitoring System Step 4 Step 3 PowerView monitoring platform support both APP and web monitoring, user can monitor Choose "Find device", then click WiFi Select corresponding router detailed running information like generating capacity, system data, and send command, set module signal signal,fill in password of the router, parameters at same time.
T「ouble Shooting Operating of the I nverte「 Automatic mode: the automatic mode can maximize the self use rate of photovoltaic power On the plant information page, click "Equipment">"Parameter Setting", Users can gene「ation, and achieve the goal of not consuming grid power as much as possible within set the inverter according to their needs the regulation range of the energy storage system.
Page 13
Operating of the I nverte「 T「ouble Shooting • Power limit setting • Valley time cha「ging Valley time charging (夏, Anti-bac团ow Valley time charging SOC(20 - 100%) • On-grid power limit(0-1 00 96) 1 00 Valley time charging power(S00 - lOOOOW) •...
Trouble Shooting Operating of the Inverter ● Peak time discharge 4 T r o u b l e S h o o t i n g This part introduces the common fault and solving steps,provides troubleshooting methods and skills to the user, and helps the user identify and solve some common faults of Peak time discharge mode Automatic power regulation the inverter.
Page 15
Trouble Shooting Trouble Shooting P022 Battery open-circuit Check the connection of battery and set P059 Battery current limited right battery SOC in each mode.Check P060 Inv trip P023 Battery SOC deadly low The inverter will recover automatically. the battery for parameter settings. P061 Transient trip Check the BMS communication cable...