Page 1
The MX400SE series can be screwed onto a mic stand or the supplied 5/8 in. 27-threaded flange. They can be easily changed from side exit to bottom exit to conceal the cabling. All models include an in-line preamplifier, a 3.66 m (12 ft.) cable.
Shure Incorporated Microflex microphones use interchangeable cartridges that allow you to choose the polar pattern for different in- stallations. Snap-Fit Windscreen • Snap into the groove below the cartridge. • To remove, spread the gap with a screwdriver or thumbnail.
• Always use the supplied windscreen or optional metal windscreen to control breath noise. • If four or more microphones will be open at the same time, use of an automatic mixer, such as the Shure SCM810 or SCM410, is recommended.
Shure Incorporated Permanent Installation Changing from Side Exit to Bottom Exit Do not cut the cable to reroute. This will compromise RF immunity. Mount the microphone using one of the following methods. Flange Slip the mounting flange retaining ring over the bottom of the preamplifier and slide it up until it is flush to the bot- tom of the flange.
Page 5
Shure Incorporated Shock Mount 1. Drill a 44mm(1-3/4 in.) diameter hole in desired mounting surface. 2. Mark and drill starter holes for screws, using shock mount as a template. 3. Secure shock mount to mounting surface with screws. 4. Thread the supplied adapter onto the MX400SE microphone before inserting it into the shock mount.
Shure Incorporated Specifications Cartridge Type Electret Condenser Frequency Response 50 to 17000 Hz Polar Pattern MX412SE/C, MX418SE/C Cardioid MX412SE/S, MX418SE/S Supercardioid Output Impedance 180 Ω Output Configuration Active Balanced 6/11...
Page 7
Shure Incorporated Sensitivity @ 1 kHz, open circuit voltage Cardioid –35 dBV/Pa(18 mV) Supercardioid –34 dBV/Pa(21 mV) 1 Pa=94 dB SPL Maximum SPL 1 kHz at 1% THD, 1 kΩ load Cardioid 124 dB Supercardioid 123 dB Equivalent Output Noise...
Page 8
Shure Incorporated Polarity Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output XLR connector Environmental Conditions Operating Temperature –18–57°C (0–135°F) Storage Temperature –29–74°C (–20–165°F) Relative Humidity 0–95% Power Requirements 11–52 V DC, 2.0 mA Cable 3.0 m (10 ft) , attached...
Page 10
Shure Incorporated Certifications Meets essential requirements of all applicable European Directives. 10/11...
Page 11
Shure Incorporated Eligible for CE marking. The CE Declaration of Conformity can be obtained from Shure Incorporated or any of its European representa- tives. For contact information please visit www.shure.com The CE Declaration of Conformity can be obtained from: www.shure.com/europe/compliance...