SEG SOLAR SEG BMA-TB Series Installation Manual

Photovoltaic module

Advertisement

Quick Links

www.segsolar.com
INSTALLATION GUIDE
Photovoltaic Module(Single-glass)
2024 V1.0
SEG SOLAR BORN AND RAISED IN THE USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SEG BMA-TB Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SEG SOLAR SEG BMA-TB Series

  • Page 1 INSTALLATION GUIDE Photovoltaic Module(Single-glass) 2024 V1.0 SEG SOLAR BORN AND RAISED IN THE USA...
  • Page 2: Table Of Contents

    www.segsolar.com TABLE OF CONTENTS 1 GENERAL INFORMATION ....................2 1.1 APPLICABLE PRODUCTS ..................2 1.2 PRODUCT IDENTIFICATION ................2 2 SAFETY ..........................3 2.1 GENERAL SAFETY ....................3 2.2 HANDLING SAFETY ....................3 2.3 INSTALLATION SAFETY ..................4 2.4 FIRE SAFETY ......................4 3 INSTALLATION .......................
  • Page 3: General Information

    Non-compliance with these instructions may void the module warranty. 1 GENERAL INFORMATION Thanks for choosing SEG Solar Photovoltaic Modules (hereafter referred to as “PV Module”), This Guide is to give information on how to apply SEG Solar PV modules properly.
  • Page 4: Safety

    www.segsolar.com 2 SAFETY 2.1 GENERAL SAFETY Be careful when unpacking, transporting, and storing the modules. They are subject to breakage if they are not handled and installed properly. It is recommended not to take them out of the packaging until the moment of the installation. During installation, please use soft materials to protect the modules from contacting directly with the ground, concrete or tiles.
  • Page 5: Installation Safety

    www.segsolar.com 2.3 INSTALLATION SAFETY Any module without a frame (laminate) shall not be considered to comply with the requirements of UL61730 unless the • module is mounted with hardware that has been tested and evaluated with the module under this standard or by a field Inspection certifying that the installed module complies with the requirements of UL61730.
  • Page 6: Installation

    www.segsolar.com 3 INSTALLATION 3.1 GENERAL INSTALLATION PRINCIPLE Modules can be installed in both landscape and portrait modes(as shown in table 1). • Module type Wiring configurations Type 1 166 SEG-XXX-BMB-HV/TB SEG-XXX-BMA-HV/TB Type 2 182 Portrait installation one row SEG-XXX-BMD-HV/TB SEG-XXX-BTD-HV/TB SEG-XXX-BMB-HV/TB SEG-XXX-BTB-HV/TB SEG-XXX-BMA-HV/TB...
  • Page 7: Location And Angle Selection

    www.segsolar.com 3.2 LOCATION AND ANGLE SELECTION It is recommended that PV modules be installed where there is excellent solar insolation. In the Northern Hemisphere, the module should typically face south, and in the Southern Hemisphere, the modules should typically face north. The most optimum installation angle varies according to different latitudes and longitudes;...
  • Page 8: Clamp Installation

    www.segsolar.com Module type Load (Pa) Installation Drawing Type 1 SEG-XXX-BMB-HV/TB SEG-XXX-BMA-HV/TB Type 2 SEG-XXX-BMB-HV/TB SEG-XXX-BTB-HV/TB +2400/ +2400/ +5400/ SEG-XXX-6MB-HV/TB -2400 -2400 -2400 SEG-XXX-6PB-HV/TB (Outer 4 (Inner 4 (8 holes) SEG-XXX-BMB-HV/TB holes) holes) Type 4 SEG-XXX-6MA-HV/TB 156&158.75 SEG-XXX-6PA-HV/TB 8 mounting holes SEG-XXX-BMA-HV/TB SEG-XXX-BMZ-HV/TB SEG-XXX-BMD-HV/TB...
  • Page 9 www.segsolar.com Drawing 1: Clamp installation on long side Drawing 2: Clamp installation on short side Installation Drawing 1 Installation Drawing 2 Module type Clamp Clamp L (mm) Load (Pa) W (mm) Load (Pa) Length Length A/8~A/4 +5400/-2400 ≥50mm SEG-XXX-BMB-HV/TB(1755×1038×35) 50~500 +3600/-2400 Type 1 B/8~B/4...
  • Page 10: Electrical Installation

    www.segsolar.com 3.5 TRACKER INSTALLATION SEG modules also have compatibility with tracker systems in the industry. The maximum load that SEG module can achieve is as listed in Table 4.(For detailed installation drawings and installation method, please refer to installation manual of tracker supplier.) Tracker installation drawing 400mm holes distance...
  • Page 11: Grounding

    To acquire the best power output, SEG recommends clients install modules with anti-PID inverters. 4 MAINTENANCE SEG Solar recommends the following maintenance items to ensure optimal performance of the module. Caution: observe the maintenance instructions for all components used in the system, such as support frames, charging regulators, inverters, batteries, etc.
  • Page 12: Cleaning

    Method B: Compressed Air SEG Solar recommends using compressed air to clean soft dirt such as dust from solar modules. However, this method should only be used if it is effective enough to clean the modules considering the on-site conditions.
  • Page 13: The Visual Inspection Of The Modules

    www.segsolar.com 4.2 THE VISUAL INSPECTION OF THE MODULES Inspect the modules visually to find if there are appearance defects, especially: • Whether the module glass is broken. • If there is burning vestige on the backsheet. • Corrosion along the cells’ bus-bar. The corrosion is caused by the dampness infiltrated into the modules when the surface encapsulation material is damaged during the installation or transportation.
  • Page 14 SEG SOLAR INC. Email: info@segsolar.com Web: www.segsolar.com SEG Headquarters: 10625 Telge Road, Houston, TX 77095...

Table of Contents