Desa Comfort Glow CG2618PV Owner's Operation And Installation Manual page 28

Unvented (vent-free) propane/lp gas log heater
Table of Contents

Advertisement

OPTIONAL
POSITIONING
OF THERMOSTAT
SENSING BULB
For Masonry and
Factory-built
Metal Fireplace
Continued
28
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Figure 29 - Locating Thermostat Sensing Bulb on Masonry Fireplace
If you have a factory-built metal fireplace, see Figure 29 for location.
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Figure 30 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace
If your fireplace has glass doors, position sensing bulb directly behind door gap on right
bottom side (see Figure 31).
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Figure 31 - Installing Thermostat Sensing Bulb behind Glass Doors
5. The mounting clip must be a minimum of 3" from bottom of fireplace to prevent
crimping of capillary. Once you have decided on a location, clean the area
thoroughly. Remove the paper backing from the adhesive on back of mounting
clip. Press the clip into the new location so that the thermostat sensing bulb will
be positioned vertically with the capillary at the bottom (see Figure 32). Slide
the thermostat sensing bulb into the clip.
IMPORTANT:
Do not crimp capillary.
Figure 32 - Positioning the Thermostat Sensing Bulb in the Vertical Position
Q Q
Q Q
Q Q
Q Q
Q Q Q
Q Q
Capillary
with the Capillary at the Bottom
Glass
Doors
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
Do Not Crimp Capillary
101992