INSTALLATION
Continued
CAUTION: Never connect heater
directly to the propane/LP supply.
This heater requires an external
regulator (not supplied). Install
the external regulator between the
heater and propane/LP supply.
Installation Items
Before installing heater, make sure you have the
items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve
with 1/8" NPT tap is an acceptable alternative to
test gauge connection. The optional CSA design-
certified equipment shutoff valve can be purchased
from your dealer. See Accessories, page 17.
If installing to a fixed fuel piping system, the
installation must conform with local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1.
If the heater will be connected to a permanent
gas source, the installer must supply an external
regulator. The external regulator will reduce in-
coming gas pressure. You must reduce incoming
gas pressure to between 11" and 14" of water. If
you do not reduce incoming gas pressure, heater
regulator damage could occur. Install the external
regulator with the vent pointing down as shown
in Figure 12. Pointing the vent down protects it
from freezing rain or sleet.
Propane/LP
Supply Tank
Figure 12 - External Regulator With Vent
Pointing Down
110373-01E
Installation must include equipment shutoff valve,
union and plugged 1/8" NPT tap. Locate NPT tap
within reach for test gauge hook up. NPT tap must
be upstream from heater (see Figure 13).
IMPORTANT: Install an equipment shutoff valve
in an accessible location. The equipment shutoff
valve is for turning on or shutting off the gas to
the appliance.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could result
in clogged heater valves.
External
Regulator
Vent
Pointing
Down
www.desatech.com
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
large enough diameter to allow
proper gas volume to heater. If
pipe is too small, undue loss of
volume will occur.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
9