Comfort Glow and CVDR30 Owner's Operation And Installation Manual page 9

Natural gas log vented decorative appliances
Hide thumbs Also See for and CVDR30:
Table of Contents

Advertisement

INSTALLATION
Continued
Test Pressures Equal To or Less Than
1/2 PSIG
1. Close manual shutoff valve (see Fig-
ure 7).
2. Pressurize supply piping system by either
using compressed air or opening main gas
valve located on or near gas meter.
3.
Check all joints from gas meter to manual
shutoff valve (see Figure 7). Apply mix-
ture of liquid soap and water to gas joints.
Bubbles forming show a leak.
4. Correct all leaks at once.
Manual Shutoff Valve
Figure 7 - Checking Gas Joints
HEARTH KIT ASSEMBLY
AND INSTALLATION
Kit Assembly
Note: The following instructions apply to
both standard single bar burners, as well as
dual flame "U" style burners. Be sure all pipe
threaded connections are tight, and have
thread compound to prevent leaks.
1. Determine which side the gas line will
be coming into the fireplace.
2. Using a hammer and screw driver, re-
move knock-out plug from the side of
the pan that corresponds to the gas line
(see Figure 8).
Knock-Out Plugs
Burner Pan
Assembly (Facing
Front of Fireplace)
Figure 8 - Knock-Out Plug Locations
901048
3. Unscrew burner inlet fitting from
burner manifold (see Figure 9).
4. Place burner manifold in pan with
threaded opening facing open knock-
out plug.
5. Using thread sealant (resistant to the
action of propane/LP gas) on larger
end of fitting, screw the burner inlet
fitting through hole and into burner
manifold. Tighten using a wrench. If
using propane/LP gas, see Propane/LP
Gas Conversion, page 10.
6. Using burner clamp, screw, and nut pro-
vided, assemble clamp to pan ("U" style
burners only). This will hold the burner
manifold in place.
7.
If using optional GA9050 series kit, go
to Optional GA9050 Series On/Off Safety
Valve/Pilot Kit section for installation in-
structions. If using optional GA9150 se-
ries kit, follow instructions included with
Gas Meter
kit for installation and operation.
Burner
Clamp
Burner
Pan
Screw
Figure 9 - Installing Burner
Installation and Gas Connection
1. Place the burner pan assembly in the
center of the fireplace floor. Make sure
the front of pan faces forward.
2. Thread the gas supply fitting to the
fireplace gas supply pipe. Use thread
sealant.
3. Install adapter fitting onto the burner
inlet fitting using thread sealant on
male threads of burner inlet fitting
(see Figure 10).
OWNER'S MANUAL
4. Install the gas connector tube to the gas
Burner Pan
Assembly (Facing
Front of Fireplace)
Figure 10 - Connecting Gas to Appliance
OPTIONAL GA9050 SERIES
ON/OFF SAFETY VALVE/
PILOT KIT ASSEMBLY
For additional convenience and safety, or
for propane/LP conversion, an optional ON/
Nut
OFF safety valve/pilot kit is available. See
Accessories, page 20.
Burner
Manifold
Natural Gas Installation
1.
Burner Inlet
Fitting
Burner Pan
Assembly
Figure 11 - Installing Gas Control Valve
9
supply fitting. Carefully shape tube to
attach to adapter fitting.
Gas Connector
Tube
Adapter
Fitting
WARNING: You must use a
ON/OFF safety valve/pilot kit for
propane/LP conversion.
Thread the gas control valve onto the
burner inlet fitting (see Figure 11). Use
thread sealant on the male threads of
the burner inlet fitting. Hold the burner
inlet fitting with a wrench to prevent
overtightening the connection to the
burner. Make sure the control rod is
facing the front (see Figure 11).
Burner Inlet
Fitting
Gas
Control
Valve
Control Rod
Continued

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cpvsr18Cpvsr24Cvdr18Cvdr24Cvsr18Cvsr24 ... Show all

Table of Contents