Summarization of Contents

Introduction
Trademarks and Legal Notices
Information regarding registered trademarks and company names.
Manual Selection and Usage Guide
Guides users on selecting and reading appropriate manuals for product usage.
Product Terms and Conditions
Warranty, Liability, and Usage Terms
Details Omron's product warranty, liability limitations, and usage guidelines.
Safety Precautions
Safety Symbol Meanings
Explains safety symbols and signal words used in the manual for hazard communication.
Critical Safety Warnings
Highlights key safety warnings related to product operation, potential hazards, and injury prevention.
Cybersecurity and Data Protection
Cybersecurity and Data Protection Measures
Outlines measures to protect against cyber threats and ensure data integrity and security.
General Safe Usage Guidelines
General Safe Usage Guidelines
Provides essential precautions for ensuring safe and proper operation of the unit.
Correct Use Precautions
Installation, Wiring, and Battery Precautions
Covers installation site requirements, wiring guidelines, and battery handling advice.
Battery Disposal Guidelines
Provides instructions for proper disposal of used batteries according to local regulations.
Mounting Screw Holes and Seals
Details specifications for mounting screw holes and the purpose of seals on the unit.
Long-Term Storage Advice
Offers recommendations for storing the product when not in use for extended periods.
Understanding the Manual
Manual Symbols and Text Guide
Explains symbols, abbreviations, and text conventions used throughout the manual for clarity.
Product Overview
ZN-DPX21-S Features and Functions
Details the key features and functionalities of the ZN-DPX21-S differential pressure station.
ZN-THX21-S Features and Functions
Details the key features and functionalities of the ZN-THX21-S thermo-humidity station.
ZN-THX11-S Features and Functions
Details the key features and functionalities of the ZN-THX11-S air thermo logger.
Product Usage Modes: Standalone and Network
Describes standalone operation and network connectivity options for the unit.
Air Particle Sensor Connectivity
Explains how to connect and integrate the Air Particle Sensor with the main unit.
Standalone Setup and Operation
Provides a step-by-step guide for setting up and operating the unit in standalone mode.
Network Connection Configuration
Details the procedures for setting up network connectivity and establishing communication.
Air Particle Sensor Setup Guide
Guides the user through the process of connecting and configuring the Air Particle Sensor.
Exterior Features
Unit Exterior Components
Identifies and labels the physical parts, ports, and connectors of the unit.
Display Unit Indicators and Meanings
Explains the meaning of various indicators shown on the unit's display screen.
Control Keys, Reset, and SD Card Handling
Describes the function of control keys, reset switch, and procedures for SD card management.
Alarm Output Functionality
Details the alarm output terminals, their operation, and electrical specifications.
Check and Preparation
Package Contents Verification
Confirms that all items listed in the package are present upon receipt.
Necessary Items for Operation
Lists all required accessories and components needed to operate the product.
Unit Assembly and Power Setup
Guides on connecting sensor heads, alarm terminals, and preparing the power source.
Performing Initial Operation Checks
Steps to follow after initial power-up to confirm the unit is functioning correctly.
PC Software: Multi Data Viewer
Introduces the PC software tools for data analysis, visualization, and device management.
Network Setup: IP Address Preparation
Prepares for network connection by defining IP addresses and subnet masks for the unit and PC.
Unit IP Address and Mode Configuration
Details steps to set the unit's IP address and select the appropriate measurement operation mode.
Modifying Unit IP Address Segments
Provides detailed instructions for changing individual segments of the unit's IP address.
PC IP Address Setup: Windows 10
Guide on setting the PC's IP address on Windows 10 for network connectivity.
PC IP Address Setup: Windows 11
Guide on setting the PC's IP address on Windows 11 for network connectivity.
LAN Cable Connection Procedure
Instructions for physically connecting the LAN cable between the unit and the PC.
Unit Mounting Methods
Describes various methods for physically installing and securing the unit.
Hook Hole and Magnet Mounting
Details mounting using hook holes and optional magnets for secure placement.
Unit Settings and Operation Modes
Operation Mode Procedures
Explains the unit's four operation modes and how to switch between them.
FUN Mode Settings Explained
Details the configurable parameters available within the FUN mode for measurement and recording.
Navigating and Changing Settings
Describes how to move through menus and modify setting values using the unit's keys.
Measurement Update Cycle (CYCLE)
Specifies the interval at which measured values are updated and recorded.
Processing Mode (MEAS) Settings
Defines how measured values are processed (e.g., NORM, MAX, MIN, AVE).
Operation Mode (MODE) Selection
Selects the primary operating mode (NORM, NET, SLEEP, PD-S).
Recording Mode (REC) Configuration
Sets how data is recorded to the SD memory card (CONT, RING).
Unit Initialization (INIT)
Resets unit settings to their factory default values.
Other Display Settings (ETC)
Controls the display of setting file and time settings in sleep mode.
Restore Settings from SD Card (RESTR)
Loads saved settings from an SD memory card back to the unit.
Save Settings to SD Card (BCKUP)
Saves current unit settings to an SD memory card for backup purposes.
Time Setting (TIME)
Allows setting the unit's internal clock for accurate timestamps.
Date and Time Component Settings
Configures the year, month, day, hour, and minute for the unit.
IP Address Configuration Enable (IP)
Controls whether the unit's IP address can be configured.
IP Address and Subnet Mask Setup
Sets the specific IP address and subnet mask for network communication.
Sleep Mode Display Settings (SDISP)
Determines if the display remains active or turns off in sleep mode.
Changing Selection Type Values
Explains how to modify settings that use predefined options.
Changing Numeric Input Values
Describes how to input and change numerical values for settings.
Threshold Settings (THR Mode)
Differential Pressure Thresholds (DP HI/LO)
Sets the upper and lower limits for differential pressure alarms.
Temperature Thresholds (DEGHI/DEGLO)
Sets the upper and lower limits for temperature alarms.
Humidity Thresholds (RH HI/LO)
Sets the upper and lower limits for humidity alarms.
Alarm Hold Setting
Determines if alarm states are maintained after the condition is cleared.
Adjustment Settings (SCL Mode)
Differential Pressure Adjustment
Calibrates differential pressure measurements by applying an offset.
Temperature Adjustment
Calibrates temperature measurements by applying an offset.
Humidity Adjustment
Calibrates humidity measurements by applying an offset.
Copying Settings Between Units
Copying Settings Between Units
Describes how to transfer settings between multiple units using an SD card.
Measurement and Recording
Selecting RUN Mode for Measurement
Activates and utilizes the RUN mode for active measurement and data recording.
RUN Mode Display (ZN-DPX21-S)
Details screen transitions and information displayed in RUN mode for ZN-DPX21-S.
RUN Mode Display (ZN-THX21/THX11-S)
Details screen transitions and information displayed in RUN mode for THX units.
Starting and Stopping Recording
Provides instructions on how to initiate and terminate data recording operations.
Outputting Recorded Data to SD Card
Procedures for saving recorded data from the unit to an SD memory card.
Clearing Held Alarms
Explains how to release active alarms that are in a maintained state.
Display Management in Sleep Mode
Controls display behavior in sleep mode to conserve power and activate display.
Connecting Air Particle Sensor
Particle Sensor Data Recording
Describes how particle sensor data is recorded alongside unit measurements.
Particle Sensor Data Graphing
Explains how to visualize recorded particle sensor data using PC software.
Appendix: Ratings and Performance
ZN-DPX21-S Ratings and Performance
Lists the technical specifications and performance characteristics of the ZN-DPX21-S.
ZN-THX21-S Ratings and Performance
Lists the technical specifications and performance characteristics of the ZN-THX21-S.
ZN-THX11-S Ratings and Performance
Lists the technical specifications and performance characteristics of the ZN-THX11-S.
Error Code Reference Guide
Lists potential error codes and recommended actions for troubleshooting unit issues.
On-Screen Display Character Guide
Provides a reference for characters and messages displayed on the unit's screen.
SD Card Data Folder Structure
Outlines the file and folder organization used on the SD memory card for data storage.
Sensor Head Calibration
States that calibration is not required for the unit, but is for the sensor heads.
Revision History
Manual Revision History
Details the history of revisions and descriptions of changes made to the manual.

Table of Contents