Desa SBVBP Owner's Operation And Installation Manual page 11

Cast iron stove and b-vent (freestanding fireplace heater) burner system for scivfc, pscivfc, and vh series stoves
Table of Contents

Advertisement

VENTING INSTALLATION
Continued
CHIMNEYS
• Complete familiarity with chimney condition, height, size, clear-
ance to combustibles and other factors is essential.
NOTICE: Consult the authority having jurisdiction
in your area regarding masonry chimney venting
applications.
NOTICE: A complete chimney inspection by a quali-
fied person should be performed.
• Appliances using B-vent connectors to vent into a masonry or
factory-built chimney should not exceed 1
every inch of connector diameter (3" vent connector has a maxi-
mum 4
1
/
foot length; 5" connector has maximum 7
2
• Oversized chimneys should be relined with appropriate listed
relining systems.
• Cleanout access may be required.
RELINING SYSTEMS
• Suitability and approval of relining materials should be determined.
• Condition, size, height, and termination of the chimney to
be relined must be determined.
• No substitution of components should be made.
• Joints and connectors should be made according to
manufacturer's instructions.
Figure 25 - Straight
Installation into Masonry
Chimney
For more information, visit www.desatech.com
For more information, visit www.desatech.com
112127-01B
1
/
feet in length for
2
1
/
foot length).
2
Figure 26 - Typical Straight
Installation with Listed Chimney
Liner
VENTING INSTALLATION
High Altitude Installation
NOTICE: Consult the authority having jurisdiction in
your area regarding listed chimney liner venting
applications.
WARNING: Operation of improperly installed and
maintained venting system could result in serious
injury, property damage, or loss of life.
HIGH ALTITUDE INSTALLATION
Your DESA B-vent burner system has been CSA tested and approved
for operation at altitudes in the USA from 0-2000 feet and in Canada
from 0-4500 feet.
When installing this burner system at an elevation above 2000 feet (in
the USA), you may need to decrease the input rating by changing the
existing burner orifice to a smaller size. Reduce input 4% for each
1000 feet above sea level. Check with your local gas company for
proper orifice size identification and proper orifice for your location.
When installing this stove and burner system at an elevation above
4500 feet (in Canada), check with local authorities.
For assistance with any high altitude installation contact DESA's
Technical Service Department at 1-866-672-6040.
11
11
Chimneys
Relining Systems

Advertisement

Table of Contents
loading

This manual is also suitable for:

SbvbnSbvbndSbvbpd

Table of Contents