Download Print this page

Gemini P 3200 Datasheet page 2

8 zone hybrid control expandable to 32 zones or 48 wireless points

Advertisement

Gemini
Control panel features
• 8 End-of-line-resistor burglary zones program-
mable for area, exit/entry delay, interior, follower,
day zone, chime, fire options, sensor watch,
swinger shutdown, zone anding and a variety of
other features
• Up to 48 points of up to 32 zones with optional
zone-expansion modules 4- zone keypad EZMs
(built-in)
• Including up to 2 2-wire fire zones
• Up to 32 individually coded users, each with a
programmable authority level
• 3 on-board relay outputs, expandable 24 external
relay outputs
• 3 keypad panics: fire, police & auxiliary
• 2 independent area partitions
• Up to 7 separate access stations by up to 32 users
• Up to 24 separately-addressable X-10 devices with
the GEM-X10KIT
• English-language prompts & system status mes-
sages from choice of keypad (8) models
• User-customized zone descriptions, reprogram-
mable as required
• 2-wire and 4-wire smoke detectors
• Reports alarms, restores and troubles by zone
• 255 event schedule
• 800 event log
• Overview mode permits monitoring and control of
total system from one keypad
• 2 programmable entry delay times
• Interior-bypass group
• Dynamic battery test interrupts charging and
places battery under load every four hours
• Chime by zone; programmable duration
• Non-volatile RAM retains memory during power
losses
• Quickloader™ programmable
• Auto-Download Log
• Exclusive V.A.L.I.D.™ feature (Verifying Automatic
Line Integrity Diagnostic) reduces false alarms due
to changes in line resistance
Communicator features
• Compatible with all major receiver formats,
including BFSK, 4/2, Modem 2, SIA, 4/3/1, 4 + 2
Express and Point ID
• Rotary dial and TouchTone™ with Rotary backup
• 3 20-digit telephone numbers
• Backup reporting, double reporting; split reporting
Compatible with these standard
GEMK1CA
4 built in zones
RP1CAe2
4 built in zones
333 Bayview Avenue, Amityville, New York 11701 USA
P3200
zone hybrid control
• 32 User codes with opening/closing reporting by
user
• AC failure reporting with programmable report
delay
• Supervised telephone line cut with programmable
delay
• Pager capability
Specifications
• Operating temperature: 0-49ºC (32-120ºF)
• Input power: 16.5Vac via Class 2 Plug-In
40VA transformer
• Loop voltage: 10-13Vdc
• Loop current:2.5mA with 2.2ohm end-of-line
resistor (model EOL2.2K); 5mA for 2-wire
smoke-detector zones
• Loop resistance: 300W max.; 50W for 2-wire
smoke detector zones
• Relay outputs (burglary; reset; aux): wet,
12Vdc, 1.2A max.; dry (cut related jumper for
dry contacts), SPDT contacts 24Vdc, 2A, 0:
6 PF
• Auxiliary power output: 12Vdc regulated
• Remote power output: 12Vdc regulated (for
keypads)
• 650 mA combined standby current (remote
power + aux. power + reset relay power)
• Standby time: residential fire/burglary & com-
mercial burglary, 4 hours min.
• EZM module: GEM-EZM8: Input, 50mA
(including PGM output. PGM output: 5mA,
12V special application
• Keypad current: GEM-RP1CAe2: 100mA;
35mA if backlighting is disabled (cut W1,
W2 & W3) PGM Output: 5mA, 12V special
application
• Maximum number of keypads: 7. Maximum
wiring length for each run (#22AWG): 1000'
divided by total number of keypads & EZMs
on run
• Designer keypad dimensions: 4 3/8" x 5 7/8"
x 1 1/6" (HWD); 11.1cm x 14.9cm x 2.7cm
(HWD)
Optional Accessories And Peripherals
• GEM-EVA: electronic voice annunciator -
unique consumer aid."Talks" users through
system operation
• VERI-PHONE: Two-way voice/listen-in module
GEMK2AS
GEMRP2ASe2
Gemini, Wizard, Adaptive and EVA are trademarks of Napco.
• WIZARD IIe: Talking alarm/appliance remote
controller works through any touch-tone
phone
• GEM-RECV8: Wireless receiver, 8 points
• GEM-RECV16: Wireless receiver, 16 points
• GEM-RECV96: Wireless receiver, 96 points
• GEM-TRANS2: Window/door transmitter,
2-point
• GEM-KEYF: Keyfob transmitter
• GEM-SMK: Wireless smoke detector
• GEM-PIR: Wireless PIR, 50x50'
• GEM-PIRPET
• GEM-RTRANS
• GEM-DT: Wireless Adaptive® Dual
Technology sensor, 40x40'
• GEM-GB: Wireless glass break detector
• GEM-WP PANIC: Waterproof panic button/
pendant
• RM3008: Relay module
• M278: Line-reversal module
• PS3002: Power-supply module, 13.2Vdc,
1.9A
• EOL130: 2-wire fire zone resistor, 130ohm,
3ohm
• EOL2.2K: End-of-line resistor assembly,
2.2ohm for fire circuit
• FT2200: End-of-line relay/resistor supervisory
module
• RB1000: Relay board
• RBAT4: Rechargeable battery, 12Vdc, 4AH
• RBATH1: Dual battery harness
• RPB-3: Universal junction box
• TRF11: Transformer, 16Vac/40VA, Class 2
• WL1: Wire assembly with lug connector
• PCD3000: Downloading software for IBM PC-
compatible
• PC12000/3000: Software with interface for
IBM-compatible computer
• PCI-MINI: Notebook computer interface
• OI163: Instruction manual
• WI818: Programming manual
ORDERING INFORMATION
• GEM-P3200: Hybrid control panel &
transformer
• GEM-P3200M: Mercantile version of above
• GEM-EZM8: 8-zone expansion zone module
Gemini keypads
GEMK3DGTL
GEMRP3DGTL
• 1-800-645-9445•
www.napcosecurity.com
A401B
GEMK4/K4RF

Advertisement

loading

This manual is also suitable for:

Gem-p3200Gem-p3200mGem-ezm8