CLEANING AND MAINTENANCE
22
Cleaning Burner Injector Holder (Cont.)
Logs

SPECIFICATIONS0

CLEANING AND
MAINTENANCE
Continued
1. Shut off the unit, including the pilot. Allow the unit to cool for
at least thirty minutes.
2. Inspect burners, pilot, and primary air inlet holes on injector
holder for dust and dirt (see Figures 45 and 46).
3. Blow air through the ports/slots and holes in the burners.
4. Check the injector holders located at the end of the burner tubes
again. Remove any large particles of dust, dirt, lint, or pet hair
with a soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the injector holders.
6. In case any large clumps of dust have now been pushed into
the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the pilot flame
indicates dust and dirt in the pilot assembly. There is a small pilot
air inlet hole about two inches from where the pilot flame comes out
of the pilot assembly (see Figure 47). With the unit off, lightly blow
air through the air inlet hole. The access hole for propane/LP pilot
is on the front of the burner carriange as shown in Figure 47. The
access hole for natural pilot is behind the pilot bracket on the top of
burner carriage (see Figure 47). You may blow through a drinking
straw if compressed air is not available.
Burner Tube
Primary Air
Inlet Holes
Figure 45 - Injector Holder On Outlet Burner Tube - Rear Burner
Primary Air
Inlet Holes
Figure 46 - Injector Holder On Outlet Burner Tubes - Front and
Middle Burners
For more information, visit www.desatech.com
For more information, visit www.desatech.com
Injector Holder
Ports/Slots
Injector
Holder
Pilot Bracket
Pilot
Assembly
Access Hole For
Cleaning PIlot
Figure 47 - Cleaning Pilot Air Inlet Hole
LOGS
• If you remove logs for cleaning, refer to Installing Logs, pages
16 and 17, to properly replace logs.
• Replace log(s) if broken or chipped (dime-sized or larger).
SPECIFICATIONS
Btu (Variable)
20,000/33,000
Type Gas
Natural: VTGF33NRA
Propane/LP: VTGF33PRA
Ignition
Electronic (Automatic)/Piezo (Manual)
Natural Gas
Manifold Pressure
3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5"
Minimum*
5"
Shipping Weight
78 lbs.
* For input adjustment
Pilot Air
Inlet Hole
Propane/LP Gas
8.0" W.C.
14"
11"
78 lbs.