OPERATING FIREPLACE

Continued
4. To lower flame, push HI/LO button on wall switch once.
Note: This fireplace does not have a pilot-only mode.
CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
HI/LO
Button
LED
Figure 37 - Control Locations
Thermocouple
Automatic
Ignitor
Electrode
Figure 38 - Pilot (Propane/LP Gas Shown)
B. Using Hand-Held Wireless Remote Control
1. Set manual ignition bypass switch on control panel to OFF
position (automatic ignition position).
2. Wait five (5) minutes to clear out any gas. Smell for gas
around heater and near floor. If you smell gas, STOP! Fol-
low "B" in the safety information on warnings plate. If you
don't smell gas, go to the next step.
3. Point remote control toward the lower front of fireplace
and push both buttons at the same time. Hold for 6 sec-
onds. The gas valve will open and electronic ignition will
begin sparking to light the pilot. Note: You will be able to
hear a clicking sound during this process. LED on wall
switch will light.
Note: You may be running this heater for the first time
after connecting to gas supply or at the start of your heat-
ing season. If so, the ON button may need to be pressed
again. This will allow air to bleed from gas system. If sev-
eral attempts to light pilot fail, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light and operate manually (see Manual Lighting Instruc-
tions for Electrical Power Outage).
4. When pilot flame is lit, the thermocouple is heated by the
flame. When thermocouple becomes hot (5 to 15 seconds),
main burner will automatically light on high flame.
For more information, visit www.desatech.com
For more information, visit www.desatech.com
110112-01A
Manual Lighting Instructions for Electrical Power Outage
5. To lower flame, point remote control toward lower front of
ON/OFF Button
Shutting Off Heater - Wall Switch
Wall Switch
Push ON/OFF button on wall switch once.
Assembly
Shutting Off Heater - Wireless Remote Control
Manual Ignition Bypass
Point remote control toward lower front of fireplace and push
Switch (Up is for
both buttons at the same time.
Remote Control)
Manual
Ignitor
Electrode
Pilot
Burner
Because this fireplace has an electronic ignition system, in the
event there is a loss of power, it will be necessary to manually
light the pilot with the piezo ignitor. After the pilot is lit, the
main burner will light automatically.
1. Follow steps 1 through 3 under Normal Lighting Instructions,
2. Set manual ignition bypass switch on control panel to ON
3. The pilot is attached to the rear of the front burner. You
HI/LO
Button
Figure 39 - Control Locations
OPERATING FIREPLACE
Normal Lighting Instructions
To Turn Off Gas To Appliance
fireplace and push HI/LO button once.
Note: This fireplace does not have a pilot-only mode.
TO TURN OFF GAS
TO APPLIANCE
MANUAL LIGHTING INSTRUCTIONS
FOR ELECTRICAL POWER OUTAGE
WARNING: You must operate this heater with the
fireplace screen in place. Make sure fireplace screen
is in place before running heater.
NOTICE: During initial operation of new heater, burning
logs will give off a paper-burning smell. Open damper or
window to vent smell. This will only last a few hours.
pages 18 and 19.
position (manual ignition position). See Figure 39.
will be able to see the pilot and spark electrode without
removing the screen or logs.
ON/OFF
LED
Button
Wall
Switch
Piezo
Ignitor
19
19
LED
Manual Ignition
Bypass Switch
(Down is ON)
Gas
Valve
Magnetic Manual
Override Handle

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vtgf33pra

Table of Contents