FIREPLACE
INSTALLATION
ELECTRICAL SUPPLY CONNECTION
CAUTION: Disconnect the
electrical power to the supply
circuit before attempting to con-
nect or service this appliance.
WARNING: This appliance,
when installed must be electri-
cally grounded in accordance
with local code or in the ab-
sence of local code, with the
current National Electric Code,
ANSI/NFPA 70, or the Canadian
Electric Code, CSA C22.1.
A pre-wired junction box receptacle with strain
relief is provided on the right side of the cabinet
for hard wiring the unit to a 15 Amp, 120VAC,
60Hz grounded branch circuit. If the installation
demands that the electrical supply be connected
from the left side, the entire receptacle box can
be relocated to the left side by following these
instructions:
Note: If you do not need to relocate the junction
box, to connect the electric supply follow steps 8
through 11 only:
1. Remove 2 screws and outer cover with strain
relief bushing on right side of cabinet (see
Figure 34).
2. Remove inner retaining screw on junction
box mounting tab.
3. Slide junction box up until screw mounting
tab is lined up to notch in outer cabinet.
J-Box Cover
with Strain
Relilef
Romex
Cable
Figure 34 - Relocating Junction Box
Receptacle and Electrical Supply
Connection
116035-01E
J-Box
Cover
J-Box Cover with
Strain Relief
J-Box with
Receptacle
Screw/Tab
Retainer
www.desatech.com
4. Swing the junction box out and slip retaining
flange out through the slot in outer cabinet.
5. Remove two screws and outer cover on the
left side of the outer cabinet.
6. Reinsert junction box retaining flange through
slot now on the left side and swing screw
mounting tab back through notch as before.
7. Slide the junction box down till mounting tab
holes line up and replace the inner retaining
screw.
8. With junction box cover removed, pull the
end of 3-wire Romex supply line through
universal strain relief bushing on cover. (see
Figure 34).
9. Strip back the outer Romex to about 4" and
connect black, white and green wires accord-
ingly using 3 wire nut connectors.
10. Tuck tailing wires into junction box and
replace junction box cover using 2 remaining
screws.
11. Tighten down strain adjustment on universal
bushing until Romex sheathing is secured.
The electrical connection is now complete.
INSTALLING OPTIONAL BLOWER
ACCESSORIES
NOTICE: If installing blower in
an existing fireplace with gas
connections, shut off gas sup-
ply and disconnect heater from
gas supply. Contact a qualified
service person to do this.
WARNING: If there is a du-
plex electrical outlet installed
in the right side of the bottom
of the fireplace base area, be
sure that the electrical power
to the outlet is turned off before
proceeding with blower instal-
lation. Failure to do this may
result in serious injury.
Model BK Installation
Follow all instructions provided in the blower
accessory kit.
1. Attach power cord to blower motor by firmly
pushing the two female terminals at the end of
power cord onto the two spade terminals on
blower motor (see Figure 35, page 22).