INSTALLING OPTIONAL CONTROLS
Continued
INSTALLING OPTIONAL WIRELESS REMOTE
CONTROL - MODEL WRC (Electronic Ignition)
Installing and Activating the Remote Receiver
1.
Open bottom louver and locate the plug receptacle. The plug
receptacle is located either on the right or left side of cabinet.
2.
The WRC model receiver does not require a battery. The re-
ceiver can be installed by first plugging the short extension
cord into the fireplace receptacle. Then plug the receiver unit
into the extension cord. Finally plug the ignition module plug
into the receiver unit (see Figure 45).
3.
Activate the remote handset battery by removing the insulat-
ing tab on the back of the handset (see Figure 46). The battery
is included pre-installed.
4.
Once the battery is activated the unit is ready to use.
5.
Replace the bottom louver panel.
Fireplace
Receptacle
Extension Cord
Figure 45 - Connecting WRC Remote Control Electronic
Battery Cover
12 Volt Battery
Back of
Handset
Figure 46 - Installing Battery into Back of Handset
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent fireplace has been tested and approved in
the USA for elevations from 0-2000 feet (610 m) and in Canada
at elevations from 0-4500 feet (1372 m).
116035-01B
Remote Control
Receiver
Ignition
Module Plug
Pull to Remove
Insulation Tab
www.desatech.com
INSTALLATING OPTIONAL CONTROLS (Cont.)
Installing Optional Wireless Remote Control - Model WRC
HIGH ALTITUDE INSTALLATION
Installing Gas Piping to Fireplace
When installing this fireplace in the USA at an elevation above
2000 feet (610 m), you may need to decrease the input rating
by changing the existing burner orifice to a smaller size. Reduce
input 4% for each 1000 feet (305 m) above sea level. Check with
your local gas company for proper derate procedure and orifice size.
When installing this fireplace in Canada at an elevation above
4500 feet (1372 m), Check with local or provincial code authorities.
Consult your local gas company to help determine the proper orifice
for your location.
For assistance with any high altitude installation contact DESA's
Customer Service Department at 1-866-672-6040.

GAS SUPPLY AND PIPING

CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If your
gas supply is not correct, do not install fireplace. See retailer where
you purchased the fireplace for proper fireplace according to your
gas type or to purchase gas conversion kit (see Accessories, page 43).
INSTALLING GAS PIPING TO FIREPLACE
WARNING: A qualified service person must con-
nect fireplace to gas supply. Follow all local codes.
CAUTION: For propane/LP units, never connect
fireplace directly to the propane/LP supply. This
heater requires an external regulator (not supplied).
Install the external regulator between the fireplace
and propane/LP supply.
External
Regulator
Vent
Pointing
Down
Figure 47 - External Regulator with Vent Pointing Down (Pro-
pane/LP Only)
GAS SUPPLY AND PIPING
Check Gas Type
Propane/LP
Supply Tank
21