Problem
LED
Description
State
ioscan (HP-
Disk
UX) lists disk
module
as NO_HW,
LED is on
or Mapper or
solid or off
dstat all
(MPE/iX) lists
no device
type
Unable to
Disk
configure
module
device for
LED is on
use by
solid or off
operating
system
HP StorageWorks Disk System 2120
Probable Cause
Disk module is faulty.
Enclosure is faulty.
If the all disks on the bus have
this problem, the cable is
faulty.
Disk module possibly not
correctly seated.
If troubleshooting an existing
installation, run diagnostics to
determine drive status.
Solution
Replace the disk
module.
Replace the enclosure
chassis.
Replace the cable.
Remove and reinstall
the disk module.
If the problem cannot
be resolved, replace
the disk module.
31