Installing The Controller Hardware; Preparing The Server; Installing The Controller Board - HP 381513-B21 - Smart Array P800 Controller RAID User Manual

For hp proliant servers
Hide thumbs Also See for 381513-B21 - Smart Array P800 Controller RAID:
Table of Contents

Advertisement

Installing the controller hardware

Preparing the server

Back up all data.
1.
Close all applications.
2.
Power down the server.
3.
CAUTION:
be powered down and the last to be powered back up. Taking this precaution ensures that the
system does not erroneously mark the drives as failed when the server is powered up.
Power down all peripheral devices that are attached to the server.
4.
Unplug the AC power cord from the outlet and then from the server.
5.
Disconnect all peripheral devices from the server.
6.

Installing the controller board

WARNING:
safety information and user documentation provided with the server before attempting the
installation.
Many servers are capable of providing energy levels that are considered hazardous and are
intended to be serviced only by qualified personnel who have been trained to deal with these
hazards. Do not remove enclosures or attempt to bypass any interlocks that may be provided
for the purpose of removing these hazardous conditions.
Remove or open the access panel.
1.
WARNING:
internal system components to cool before touching them.
Select an available x8 or larger PCIe slot.
2.
Remove the slot cover. Save the retaining screw, if one is present.
3.
Slide the controller board along the slot alignment guide, if one is present, and press the board
4.
firmly into the slot so that the contacts on the board edge are properly seated in the system board
connector.
Secure the controller board in place with the retaining screw. If the slot alignment guide has a latch
5.
(near the rear of the board), close the latch.
Connect storage devices to the controller. (For details of the procedure, see "Connecting storage
6.
devices (on page 10).")
Close or replace the access panel, and secure it with thumbscrews, if any are present.
7.
In systems that use external data storage, be sure that the server is the first unit to
To reduce the risk of personal injury or damage to the equipment, consult the
To reduce the risk of personal injury from hot surfaces, allow the drives and the
Installing the controller hardware 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smart array p800

Table of Contents