Download Print this page
Panasonic MCO-170AICUV-PE Operating Instructions Manual

Panasonic MCO-170AICUV-PE Operating Instructions Manual

Co2

Advertisement

Please read the operating instructions carefully before using this product, and save the operating
instructions for future use.
See page 91 for all model numbers.
Operating Instructions
MCO-170AIC
MCO-170AICUV
MCO-170AICUVH
CO
Incubator
2
MCO-170AIC
MCO-170AICUV
MCO-170AICUVH
Series

Advertisement

loading
Need help?

Need help?

Do you have a question about the MCO-170AICUV-PE and is the answer not in the manual?

Questions and answers

Summarization of Contents

INTRODUCTION
Intended Use and Precautions
Describes the designed purpose and precautions for using the equipment.
PRECAUTIONS FOR SAFE OPERATION
Safety Symbols and Warning Definitions
Explains warning and caution signs, and their associated meanings for user safety.
LABELS ON INCUBATOR
Warning Safety Labels
Details warning labels applied to the incubator, their locations, and the dangers they represent.
SYMBOLS ON INCUBATOR
Incubator Symbol Meanings
Describes common symbols found on the incubator and their meanings for safe operation.
INCUBATOR COMPONENTS
Unit Components Overview
Provides a visual overview of the incubator unit with numbered components.
Detailed Component Descriptions
Provides detailed descriptions for each numbered component of the incubator unit.
LCD Touch Panel Display Elements
Explains the layout and function of the main display screen of the LCD touch panel.
LCD Touch Panel Function Keys
Details the function of each numbered display element and key on the LCD touch panel.
Specific LCD Touch Panel Keys
Explains the function of specific keys on the LCD touch panel like H2O2, Unlock, and Buzzer keys.
Remote alarm terminal
Remote Alarm Connection and Behavior
Describes the remote alarm terminal connection and its behavior with the buzzer key.
INSTALLATION
Installation Site Requirements
Specifies the environmental and physical requirements for installing the incubator.
Initial Installation and Setup
Details the initial steps for installation, including cleaning and setting up internal components.
Grounding and Safety Precautions
Explains the importance of proper grounding and cautions against climbing or stacking without brackets.
Connecting the CO2 Gas Supply
Provides instructions on connecting the CO2 gas cylinder and setting the gas pressure.
BEFORE COMMENCING OPERATION
Initial Cleaning Procedure
Outlines the steps for thorough initial cleaning of the incubator chamber and its components.
Removing Inner Attachments
Details how to remove trays, humidifying pan, cover, and fan cover for cleaning.
Re-installing Inner Attachments
Guides on how to correctly re-install the fan, duct, and fan cover after cleaning.
Filling the Humidifying Pan
Provides instructions for filling the humidifying pan with sterile distilled water.
FOR BETTER CULTIVATION
Precautions for Cultures
Offers essential precautions for maintaining optimal culture conditions and preventing issues.
Preventing Contamination
Advises on selecting the right site and practices to prevent contamination within the chamber.
CORRECT OPERATION
Starting Trial Operation
Guides through the initial setup and startup procedures for the incubator.
BASIC OPERATION ON LCD TOUCH PANEL
Navigating the Menu Structure
Illustrates how to navigate through the menu structure using the LCD touch panel.
Direct Operation from Main Screen
Explains how to operate specific functions directly from the main screen like CO2 gas supply and H2O2.
BASIC PARAMETERS
Numerical Input Method
Describes how to input numerical values using the touch panel's input windows and keys.
Setting Temperature and CO2 Density
Guides on setting chamber temperature, CO2 density, and high limit temperature alarms.
Setting High Limit Temperature Alarm
Details setting chamber temperature, CO2 density, high limit alarm, and notes on initial operation.
Configuring the Key Lock Function
Explains how to enable and set a password for the key lock function on the touch panel.
Key Lock Operation and Password Handling
Details the operation of the key lock, including password entry and incorrect password handling.
Removing the Key Lock Function
Guides on how to disable the key lock function and remove it.
ALARM PARAMETERS
Setting Temperature and CO2 Alarms
Describes how to configure automatic set temperature and CO2 density alarm settings.
Configuring Alarm Delays and Ring Back
Explains settings for alarm delay, door delay, ring back, and remote alarm functions.
OPERATION/ALARM LOG
Setting Log Interval
Guides on setting the interval for saving operation log data.
Displaying Operation Log Graphs
Explains how to view saved operation logs graphically on the LCD touch panel.
Viewing Specific Log Data Graphs
Details how to select and display graphs for temperature, CO2, and door opening logs.
Exporting Operation Log Data to USB
Guides on exporting operation log data to USB memory in CSV format.
Displaying Alarm Log Data
Explains how to view saved alarm logs graphically on the LCD touch panel.
Viewing and Exporting Alarm Logs
Details how to display and export alarm logs, including filtering by date.
OTHER PARAMETERS
Setting Date and Time
Provides instructions for setting the current date and time on the incubator.
Adjusting Brightness and Sleep Settings
Guides on adjusting the LCD screen brightness and configuring sleep mode settings.
Configuring DAQ System Parameters
Details how to configure parameters for the Data Acquisition System (DAQ) MTR-5000.
UV LAMP PARAMETERS
Using the UV Lamp for Disinfection
Explains how to use the UV lamp for disinfection, including precautions and operating conditions.
Setting UV Lamp ON Period
Guides on changing the preset ON period for the UV lamp.
Lighting UV Lamp for 24 Hours
Provides a procedure for using the UV lamp continuously for 24 hours for chamber decontamination.
H2O2 DECONTAMINATION
H2O2 Decontamination Precautions
Lists essential warnings and cautions for performing H2O2 decontamination safely and effectively.
H2O2 Decontamination Procedure Steps
Outlines the step-by-step process for performing H2O2 decontamination using the incubator.
H2O2 Decontamination Process Stages
Describes the different stages (Step 1 to Step 4) of the H2O2 decontamination process.
H2O2 Decontamination Stages Overview
Details the remaining stages (Step 3, Step 4) of the H2O2 decontamination process, including warming and vapor generation.
H2O2 Gas Resolve and Completion
Covers the H2O2 gas resolve stage and the completion of the decontamination process.
Handling H2O2 Reagent and Unlock Key
Provides precautions for handling H2O2 reagent and using the unlock key.
ELECTRIC LOCK (OPTION)
Setting Auto Lock Function
Guides on how to enable and configure the auto lock function for the outer door.
Removing Auto Lock Function
Guides on how to disable the auto lock function for the outer door.
GAS AUTO CHANGER (OPTION)
Connecting CO2 Gas Cylinders for Auto Changer
Details the process of connecting two CO2 gas cylinders for the auto changer.
Automatic CO2 Supply Line Changeover
Explains how the indicator lights and select key work during automatic CO2 supply line changeover.
Manual CO2 Gas Supply Line Changeover
Guides on manually changing the CO2 gas supply line between cylinders.
STD GAS AUTO CALIBRATION KIT (OPTION)
Connecting Standard Gas Cylinder for Calibration
Explains how to connect a standard gas cylinder for CO2 density calibration.
Setting CO2 Density for Calibration
Guides on inputting the CO2 density of the standard gas cylinder for calibration.
Performing CO2 Density Calibration
Details the steps for performing the CO2 density calibration process.
ROUTINE MAINTENANCE
Monthly Cleaning Procedure
Provides instructions for routine monthly cleaning of the incubator's chamber and attachments.
ALARMS, SAFETY, AND SELF-DIAGNOSIS
Alarm and Safety Functions Overview
Lists alarms, safety functions, and self-diagnostic functions for culture operations.
Alarm Behavior with Buzzer Key
Explains how alarms behave with the buzzer key, including ring back function.
H2O2 Decontamination and Gas Calibration Alarms
Details alarms related to H2O2 decontamination and STD gas calibration.
TROUBLESHOOTING
Incubator Not Operating or Alarm Activated
Offers troubleshooting steps for when the incubator doesn't operate or an alarm is active.
Temperature, Humidity, and CO2 Issues
Provides troubleshooting for temperature, humidity, and CO2 density discrepancies.
H2O2 Decontamination and UV Lamp Issues
Offers solutions for problems with H2O2 decontamination or UV lamp functionality.
DISPOSAL OF UNIT
Safe Unit Disposal Procedures
Advises on the proper procedure for dismantling and disposing of the CO2 incubator.
SPECIFICATIONS
General Product Specifications
Lists the general specifications for the CO2 incubator models MCO-170AIC, UV, and UVH.
Optional Accessories and Compatibility
Details optional accessories and their compatibility for different incubator models.
PERFORMANCE
Performance Characteristics
Outlines the performance specifications like temperature control, CO2 control, and humidity.
Safety check sheet
Service Engineer Safety Checklist
Provides a form for service engineers to check unit contents, contamination, and safety before maintenance.