Table of Contents

Advertisement

Quick Links

TRIO PACK
Instructions and warnings
IE
Installer
ELECTRIC
User
Maintenance technician
4 - 6 - 9
Heat pump consisting of:
- indoor unit
UI TPE
- outdoor condensing unit
AUDAX PRO 4 - 6 - 9 V2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TRIO PACK ELECTRIC 6 and is the answer not in the manual?

Questions and answers

Summarization of Contents

1 INSTALLING THE INDOOR UNIT
1.1 DESCRIPTION OF THE PRODUCT
Details the components of the Trio Pack Electric heat pump system.
1.2 INSTALLATION RECOMMENDATIONS
Guidelines for safe and proper installation, including PPE.
1.3 SOLAR CONTAINER INDOOR UNIT MAIN DIMENSIONS
Provides detailed technical drawings and dimensions for the indoor unit.
1.4 CONNECTION TEMPLATE
Details the electrical and hydraulic connection points for the system.
1.5 INSTALLATION
Lists the components included in the indoor unit package.
1.6 HYDRAULIC CONNECTION
Instructions for performing hydraulic connections, emphasizing cleaning.
1.7 SAFETY VALVE DRAIN
Details how to connect safety valves to a draining funnel for safe operation.
1.8 ELECTRICAL CONNECTIONS TO THE MAIN PANEL
Explains electrical connections to the main panel, including cable routing and terminals.
1.9 CHILLER LINE INSTALLATION
Instructions for connecting the chiller line of the outdoor unit, including insulation advice.
1.10 TRIO PACK REMOTE PANEL
Provides dimensions and overview of the Trio Pack remote panel.
1.11 REMOTE PANEL INSTALLATION OPERATIONS
Step-by-step guide for installing the remote panel and making connections.
1.12 ELECTRICAL CONNECTION
Details electrical safety requirements, including earthing and power specifications.
1.13 ZONE REMOTE CONTROL (OPTIONAL)
Instructions for configuring the zone remote control via DIP switches.
1.14 MODBUS TEMPERATURE AND HUMIDITY ROOM PROBES (OPTIONAL)
Explains the use and connection of Modbus temperature and humidity probes.
1.15 DOMINUS (OPTIONAL)
Information on remote control using the optional Dominus kit.
1.16 ROOM CHRONO-THERMOSTATS (OPTIONAL)
Details on applying room chrono-thermostats and their electrical connection.
1.17 HUMIDISTAT ON/OFF (OPTIONAL)
Instructions for making a dehumidification demand using a humidistat.
1.18 EXTERNAL TEMPERATURE PROBE (OPTIONAL)
Information on using an external probe for temperature reading and thermoregulation.
1.19 TEMPERATURE CONTROL SETTING
Explains how to adjust flow temperature based on outdoor temperature using menus and curves.
1.20 ANTIFREEZE PROTECTION
Details on the antifreeze kit, its installation, and minimum temperature protection.
1.21 SYSTEM FILLING
Instructions for filling the system, including vent valves and pressure settings.
1.22 OPERATING LIMITS
Charts showing operating limits for cooling, CH, and DHW modes based on temperatures.
1.23 INDOOR UNIT START-UP (IGNITION)
Steps for commissioning the heat pump, including checks and parameter settings.
1.24 CIRCULATION PUMP
Explains the function and adjustment of heat pump and zone circulators, including LEDs and other functions.
1.25 DOMESTIC HOT WATER STORAGE TANK UNIT
Details the storage tank unit, its capacity, heat exchangers, and components.
1.26 KITS AVAILABLE ON REQUEST
Lists optional kits such as recirculation, polyphosphate dispenser, and expansion kits.
1.27 MAIN COMPONENTS KIT
Provides a key to identify all main components of the appliance.
2 INSTRUCTIONS FOR USE AND MAINTENANCE
2.1 GENERAL WARNINGS
Safety precautions for using the appliance, especially regarding children and electrical safety.
2.2 CLEANING AND MAINTENANCE
Importance of yearly maintenance for system integrity, safety, and performance.
2.3 TRIO PACK ELECTRIC REMOTE PANEL (MAIN)
Overview of the main remote panel, its display, and system use.
2.3.4 DHW (Domestic hot water) set setting
How to set domestic hot water temperature for optimal comfort.
2.3.5 Fault and anomaly warnings
How the system signals anomalies and how to reset them.
List of anomalies outdoor condensing unit
Lists error codes and solutions for the outdoor condensing unit.
2.4 USING THE SECONDARY ZONE REMOTE PANEL (OPTIONAL)
How to use a secondary zone remote panel for general operation.
2.5 RESTORE CENTRAL HEATING SYSTEM PRESSURE
Steps to check and restore central heating system pressure.
2.6 DRAINING THE SYSTEM
Procedure for draining the heating system, including vent valves.
2.7 DRAINING THE DOMESTIC HOT WATER CIRCUIT
How to drain the domestic hot water circuit.
2.8 DECOMMISSIONING
Procedures for permanent system shutdown, requiring professional staff.
3 MAINTENANCE AND INITIAL CHECK INSTRUCTIONS
3.1 GENERAL WARNINGS
Safety warnings for personnel performing maintenance and installation.
3.2 INITIAL CHECK
Steps to commission the package, including documentation and electrical checks.
3.3 YEARLY EQUIPMENT CHECK AND MAINTENANCE
Annual checks and maintenance tasks to ensure appliance safety and efficiency.
3.4 EXTERNAL UNIT FINNED AIR COIL MAINTENANCE
Recommendations for cleaning the finned air coils of the external unit.
3.5 HYDRAULIC DIAGRAM
A detailed diagram illustrating the hydraulic layout and components of the system.
3.6 WIRING DIAGRAM
A diagram showing the electrical connections and wiring of the appliance.
3.7 POSSIBLE PROBLEMS AND THEIR CAUSES
Lists common problems, their causes, and suggests solutions.
3.8 SYSTEM PROGRAMMING
Guide to programming system parameters via the Assistance menu for customization.
3.9 PROGRAMMING AND USE OF THE ZONE REMOTE PANEL
Configuration steps for using remote panels for zone control.
3.10 FIRST IGNITION PARAMETER SETTING
Guide to setting initial parameters for generator operation and system configuration.
3.11 DHW (DOMESTIC HOT WATER) BOOST FUNCTION
How to activate the DHW boost function using electrical resistance.
3.12 ANTI-LEGIONELLA FUNCTION
How to perform a thermal shock to prevent Legionella bacteria.
3.13 HEAT PUMP CIRCULATOR FUNCTION
How to define the operating mode of the heat pump circulator.
3.14 PUMP ANTI-BLOCK FUNCTION
Function to prevent pump locking due to prolonged inactivity.
3.15 3-WAY ANTI-BLOCK SYSTEM
Function to activate the motorised 3-way unit to prevent blocking.
3.16 SYSTEM SETPOINT CORRECTION FUNCTION
How to activate a function to correct setpoints based on hydraulic disconnections.
3.17 PHOTOVOLTAIC FUNCTION
How the system utilizes photovoltaic energy for DHW heating.
3.18 INTEGRATION WITH THE SYSTEM ELECTRICAL RESISTANCES
How to integrate system electrical resistances for central heating.
3.19 ZONE 2 SAFETY THERMOSTAT FUNCTION
How the zone 2 safety thermostat checks flow temperature and limits.
3.20 CONJUNCTION MODE
How the system prioritizes DHW and system requests using alternating logic.
3.21 HEAT PUMP DISABLING FUNCTION
How to inhibit heat pump operation using a contact.
3.22 DIVERTER VALVE MANAGEMENT (SUMMER / WINTER) (OPTIONAL)
How to manage summer/winter diverter valves using the unit's 230V outlet.
3.23 EXTERNAL PROBE SETTING (OPTIONAL)
How to activate and correct optional external probe settings.
3.24 MANUAL DRIVES
How to manage appliance loads in manual mode for troubleshooting.
3.25 OUTDOOR CONDENSING UNIT TEST MODE FUNCTION
Instructions for using the outdoor unit test mode.
3.26 OUTDOOR CONDENSING UNIT PUMP DOWN FUNCTION
Instructions for using the outdoor unit pump down function.
3.27 SUPERVISION DEVICE CONFIGURATION
How to configure the appliance for external supervision devices.
3.28 YEARLY MAINTENANCE
Annual checks for storage tank integrity, assembly tightness, system condition, and leaks.
3.29 DECOMMISSIONING
Procedures for permanent system shutdown, requiring professional staff.
4 TECHNICAL DATA
4.1 TECHNICAL DATA TABLES
Tables listing nominal data for various operating conditions and applications.
4.2 TRIO PACK ELECTRIC 4 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811/2013)
Energy efficiency label for the Trio Pack Electric 4 model.
4.3 TRIO PACK ELECTRIC 6 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811/2013)
Energy efficiency label for the Trio Pack Electric 6 model.
4.4 TRIO PACK ELECTRIC 9 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811/2013)
Energy efficiency label for the Trio Pack Electric 9 model.
4.5 PARAMETERS FOR FILLING IN THE PACKAGE FICHE
Instructions and facsimile for filling in the package fiche for room central heating systems.

Table of Contents