(digit 13 to 15). Note This document and other information from Parker Hannifin GmbH & Co KG, its subsidiaries, sales offices and authorized distributors provide product or system options for further investigation by users having technical expertise.
Max. length 2 m, otherwise use larger 2 – 3 times diameter and, even at lowest fluid pipe diameter than port size. level, approx. 200 mm below fluid level. Inlet pres- Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
Page 4
M14x1.5 (outlet) port L2 For side mounting (suction port facing down) use alternative drain port 1 (cw rotation) or 2 (ccw rotation). Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
Page 5
– be used to The drive shaft should only carry true torque. keep the pump case filled, to warm up the pump Contact Parker for allowable side loads or axial (during cold temperature operation) or for better forces.
(HFC, HFD, bio degradable or synthetic Suction filter should be avoided. Suction conditions fluids) please contact Parker and review the Hy- will be affected. Filter can be blocked and cause draulic Fluids Information in Catalogue 2500/UK.
Page 7
By using adapter kit PVCMCK** (below 47de- sign) / PVCCK** (since 47 design) the standard pressure adjustment Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
For more details on the different compensator pump outlet pressure is equal to the compensator options see also the PV compensator spare parts differential setting. Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
Beside the version shown above (code ...MFC) compensator accessories code PVAC..also a version ...MF1 with a topside NG6 / D03 Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
The factory setting of the flow compensator is two separate compensator valves for flow (load sensing) and pressure compensation. 10 ± 1 bar, the adjustment for the pressure com- Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
For a horse power compen- sator with load sensing, code ...*C* a modified lock nut load sensing compensator is used. Horse power pilot cartridge Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
(compensator code ends with..Z). Al two direct-action pressure cartridge valves is used other versions include an integrated pilot valve. to pilot the pump. lock nut set screw Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
Page 13
The compensator spring chamber is releived to case drain, the pump is compensating PVAC1P... PVACPP PVAC2P... PVAC2M... PVAC1E... at min. compensating pressure (stand-by). (PVAC2E...) Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
Make sure connection is wide enough and has not too much pressure drop. Reason Differential pressure at compensator is adjusted improperly (too low). Solution Check differential pressure adjustment and correct it as described above. Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
Page 15
& Co KG Parker Hannifin Manufacturing Germany GmbH Pump & Motor Division Europe Neefestr. 96 09116 Chemnitz Tel.: +49-(0)371 / 3937-0 Fax: +49-(0)371 / 3937-488 Internet: www.parker.com/pmde Parker Hannifin Manufacturing Germany GmbH & Co. KG Pump & Motor Division Europe Chemnitz, Germany...
Page 16
Series PV, series 47 and higher Position notification regarding Machinery Directive 2006/42/EC: Products made by the Pump & Motor Division Europe (PMDE) of Parker Hannifin are excluded from the scope of the machinery directive following the “Cetop” Position Paper on the implementation of the Machinery Directive 2006/42/EC in the Fluid Power Industry.
Need help?
Do you have a question about the PV080 and is the answer not in the manual?