Effective:
January 1, 2012
Supersedes:
All Others
PGP600 Series

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PGM600 and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker PGM600

  • Page 1 Service Manual HY09-SM600/US Service Manual PGP/PGM600 Effective: January 1, 2012 Supersedes: All Others PGP600 Series...
  • Page 2: General Information

    Offer of Sale The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the “Offer of Sale”.
  • Page 3: General Instructions

    General Instructions 610/620/640 Service Manual Single Pump General Instructions These service instructions will familiarize SAE 2- or 4-Bolt Case Hardened Gears you with Parker’s single and multiple pumps: Mountings • their component parts Balanced Thrust • Plates Minimize Long Shaft the relative position of each part Friction &...
  • Page 4 PGP/PGM600 Series Catalog HY09-SM600/US Service Manual PGP/PGM600 Exploded View PGP/PGM600 Exploded View ITEM DESCRIPTION Flange Body Drive Gear-Shaft Gear, Driven Screw, Drive Nut, Hex Name Plate Ring, Snap Stud Pump Seal Elem Pump Seal Energ Seal, Lip Balance Plate Washer...
  • Page 5: Tool List

    PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Tool List Tool List • Arbor press • Awl • 1 1/2” Dia. steel ball • Clean, lintless cloths • Deburring tool (an old file with cutting teeth ground off) • Machinist’s hammer • Soft hammer •...
  • Page 6 PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Disassembly Information Start Disassembly Here CAUTION: 1. If prying off sections becomes necessary, take extreme care not to mar or damage machined surfaces. Excessive force while prying can result in misalignment and seriously damage parts.
  • Page 7: Disassembly Information

    PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Disassembly Information 7) Remove the snap ring 8) Push out the (located in front of the shaft seal. shaft seal ring). 9) Inspect all bushings for 10) Clean all faces of scoring or discoloration the body and mounting and replace if necessary.
  • Page 8 PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Assembly Information Start Assembly Here 2) Any bushings removed 1) If the bushings have from the flange and body been removed, deburr should be replaced and the bushing bores with assembled in the drive an emery cloth.
  • Page 9: Assembly Information

    PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Assembly Information 10) Assemble new 9) Check balance plates sealing parts, the rubber and the sealing parts. seal first, the plastic seal on top. (Pump plate and seals.) The instructions for proper installation for a 2 piece seal are as follows: 1.
  • Page 10 PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Assembly Information 16) Fit the mounting flange 17) Thread the fasteners careful from the top down to into the body and tighten the body. Fit the interlocking alternately or cross track correctly. corner. Torque diagonally opposed fasteners to correct torque.
  • Page 11 PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Wear Guideline Guideline for acceptable wear Body Bushings Wear in excess of .005” cut-out necessitates Bushings must be replaced if PTFE coating replacement of the body. Place a straight-edge is worn through or if scored or blackened.
  • Page 12 PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Hydraulic Oil Recommendation Hydraulic Oil Recommendation When choosing your Hydraulic Oil, duty cycle and oil tem- The opposite is true when the fluid cools, its viscosity perature must be factored in to optimize your system perfor- increases.
  • Page 13 PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Hydraulic Oil Recommendation Petroleum Oils (Mineral-Based) Viscosity Recommendations Cold Weather Operation Oils for use in cold weather should have a viscosity not • Optimum operating viscosity is considered exceeding 7500 SUS (1620 cSt) at the minimum start up to be about 100 SUS (20 cSt).
  • Page 14 3000 psi (2000/2500 psi in the wider gear widths) should be In general these oils have low viscosity and may be used only reviewed with your Parker sales representative at reduced operating pressures and oil temperatures Water-in Oil (60/40) invert Emulsions...
  • Page 15: Start-Up Procedure

    PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Start-up Procedure Recommended Start-up Procedure For New or Rebuilt Pump Before installing a new or rebuilt pump, back off the main relief valve until the spring tension on the adjusting screw is relieved. This will avoid the...
  • Page 16: Recommended Test Procedure

    PGP/PGM600 Series Catalog HY09-SM600/US Service Manual Test Procedure Recommended Test Procedure Many repairmen measure the output at normal operat- Make certain that there is an adequate supply of oil ing speed and at zero pressure, then again at 1000 psi for the pump;...
  • Page 17: Offer Of Sale

    The items described in this document and other documents or descriptions provided by Parker Hannifin Corporation, its subsidiaries and its authorized dis- tributors are hereby offered for sale at prices to be established by Parker Hannifin Corporation, its subsidiaries and its authorized distributors. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions.
  • Page 18: Product Information

    Our will receive prompt attention by calling the Parker Prod- Company has the largest distribution network in its uct Information Center at our toll-free number: field, with over 7,500 distributors serving more than 1-800-C-PARKER (1-800-272-7537).

This manual is also suitable for: